Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PERFORMANCE CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PERFORMANCE CONSTRUCTION LLC in 926 MENOMONIE STREET, EAU CLAIRE, WI 54701 (NAICS 238160). OSHA activity number 334443934.

Watch Performance Construction LLC — free Get an email when a new federal OSHA severe-injury report for Performance Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
926 MENOMONIE STREET
City
EAU CLAIRE
State
WI
ZIP
54701
Mailing
1106 BRIGGS AVE, EAU CLAIRE, WI 54703
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  (a) Residential roofing project, Menomonie Street, Eau Claire, WI; An effective means of eye protection was not used while performing roofing activities with a pneumatic nail gun.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.501 B13

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision:  (a) Residential roofing project, Menomonie Street, Eau Claire, WI; An effective means of fall protection was not used while performing roofing activities at elevations of 17 feet 8 inches or greater.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.503 B01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:  (a) Residential roofing project, Menomonie Street, Eau Claire, WI; The employer did not verify compliance with fall protection training by preparing a written certification.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; and, because of other portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and the ladder was not secured at its top:  (a) Residential roofing project, Menomonie Street, Eau Claire, WI; Extension ladders did not extend three for or more past landing area at the eaves and portable that could not extend three feet past landing area were not secured.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.1053 B04

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  (a) Residential roofing project, Menomonie Street, Eau Claire, WI; A step ladder was folded and used to gain access from the roof of the first story to the eaves of second story during the roofing project.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334443934.