PHILADELPHIA, PA —
OSHA Inspection: HOUSING SOLUTIONS
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of HOUSING SOLUTIONS in 933 BAINBRIDGE ST, PHILADELPHIA, PA 19147 (NAICS 236116). OSHA activity number 334479532.
Where did this inspection happen?
- Establishment
- HOUSING SOLUTIONS
- Site address
- 933 BAINBRIDGE ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19147
- Mailing
- 8317 CHILDS RD, GLENSIDE, PA 19038
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as follows: a) Jobsite: 933 Bainbridge St, Philadelphia, PA. - On or about 5/25/12, the working platforms on the supported tubular welded frame scaffold were missing planks. Employees installing facial boards on the 3 story residential building were working from the 4th and 5th platforms, approximately 33 ft. above ground level.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1926.451 B05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(5)(i): Each end of a platform 10 feet or less in length extended over its support more than 12 inches. a) Jobsite: 933 Bainbridge St, Philadelphia, PA. - On or about 5/25/12, the cantilevered portion of the platforms on the supported tubular welded frame scaffold extended more than 12 inches over their support which exposed the employees to tip over hazards. Employees installing facial boards on the 3 story residential building were working from the 4th and 5th platforms, approximately 33 ft. above ground level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Penalty
- Initial $2800.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite: 933 Bainbridge St, Philadelphia, PA. - On or about 5/25/12, employees were not provided with a fall protection system while working from a supported tubular welded frame scaffold. Employees installing facial boards on the 3 story residential building were working from the 4th and 5th platforms, approximately 33 ft. above ground level.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1926.451 E01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(1): Portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used on scaffold platforms more than 2 feet (0.6 m) above or below a point of access. a) Jobsite: 933 Bainbridge St, Philadelphia, PA. - On or about 5/25/12, a safe means of access was not provided for employees working on the supported tubular welded frame scaffold. Employees installing facial boards on the 3 story residential building were working from the 4th and 5th platforms, approximately 33 ft. above ground level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Jobsite: 933 Bainbridge St, Philadelphia, PA. - On or about 5/25/12, an employee was not trained to recognize the hazards associated with his work while working from a supported tubular welded frame scaffold. The employee was installing facial boards from the 5th working platform, approximately 33 ft. above ground level
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Penalty
- Initial $2800.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Jobsite: 933 Bainbridge St, Philadelphia, PA. - On or about 5/25/12, an employee was exposed to fall hazards because he was not using a fall protection system while working over an unprotected edge from the roof of a 3 story residential apartment building. The employee was installing facial boards on the face of the building approximately 36 ft. above ground level.
Recent events (2)
- — I (S) $1000
- — Z (S) $2800
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. a) Jobsite: 933 Bainbridge St, Philadelphia, PA. - On or about 5/25/12, an employee was exposed to fall hazards without any fall protection training. The employee was installing facial boards over an unprotected edge from the roof of a building approximately 36 ft. above ground level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HOUSING SOLUTIONS
PHILADELPHIA, PA—2014-08-07 00:00:00
HOUSING SOLUTIONS
View HOUSING SOLUTIONS's full OSHA safety record →
More inspections in this industry (NAICS 236116)
PLAIN CITY, OH—2026-07-09
RUSCILLI CONSTRUCTION
IRVINE, CA—2026-07-09
TOLL BROTHERS INC.
ROSEVILLE, CA—2026-07-09
JERRY LEE STAIRS INC.
NEWPORT, RI—2026-07-08
PEZZUCO CONSTRUCTION INC.
EVANSVILLE, IN—2026-07-08
L & J CONSTRUCTORS, LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334479532.