Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JIRO CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JIRO CONSTRUCTION in 8154 E. 33RD AVE., DENVER, CO 80238 (NAICS 238130). OSHA activity number 334594736.

Watch Jiro Construction — free Get an email when a new federal OSHA severe-injury report for Jiro Construction is published. One employer, no account, unsubscribe in one click.
Establishment
JIRO CONSTRUCTION
Site address
8154 E. 33RD AVE.
City
DENVER
State
CO
ZIP
80238
Mailing
4625 W. 6TH AVE. APT 1, DENVER, CO 80204
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 19 instances 6 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it was infeasible or that it created a greater hazard to use these systems, and did not develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a)  Jiro Construction at 8154 E. 33rd Ave., Denver, CO 80238:  On or before June 2, 2012, the employer did not ensure that employees were protected from falling in the following instances:    1)  An employee was sheathing the roof with a 12 in 12 pitch without the use of fall protection; and    2)  Employees were framing on the second floor of this house, and 18 window wall openings had their base set at 36".  No guardrails were in place over the window wall openings.    Conditions exposed employees to fall hazards of up to 25 feet from ground to eave.      Abatement note:  1926.502(b) provides that the top height of a guardrail system shall be 42 inches +/- 3 inches.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1926.1053 B13

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $510.00 Reduced
29 CFR 1926.1053(b)(13):  The top or top step of a stepladder was used as a step:    a)  Jiro Construction at 8154 E. 33rd Ave., Denver, CO 80238:  On or before June 2, 2012, the employer provided a 6 foot stepladder for use in accessing the upper trusses about 10' high, and the top and top step of the ladder was used as a step.  Condition exposed employees to fall hazards of up to 10 feet from the second floor to the roof trusses.