SAINT CHARLES, MO —
OSHA Inspection: LMI AEROSPACE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LMI AEROSPACE INC. in 3600 MUELLER ROAD, SAINT CHARLES, MO 63301 (NAICS 336413). OSHA activity number 334598331.
Where did this inspection happen?
- Establishment
- LMI AEROSPACE INC.
- Site address
- 3600 MUELLER ROAD
- City
- SAINT CHARLES
- State
- MO
- ZIP
- 63301
- Mailing
- 3030 HIGHWAY 94 NORTH, SAINT CHARLES, MO 63301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336413
- Employees
- 104
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Inside of the Production Work Center 25 - CNC/CMM, specific procedures were not developed in writing for the following machines: a/ Zimmerman FZ-35, NC 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. b/ SHODA NC-145 6-Axis Milling Machine, unlnown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. c/ Zimmerman FZ-30 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. d/ DMS #1 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. e/ DMS #2 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. f/ Fadal #1 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 pneumatic. g/ Fadal #2 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. h/ Fadal #3 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic.
Recent events (2)
- — I (O) $5000
- — Z (S) $5000
1910.147 C05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: Inside of the Production Work Center 25 - CNC/CMM, suitable hardware was not provided to isolate the pneumatic energy disconnect for the following machines: a/ Zimmerman FZ-35, NC 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. b/ SHODA NC-145 6-Axis Milling Machine, unlnown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. c/ Zimmerman FZ-30 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. d/ DMS #1 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. e/ DMS #2 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. f/ Fadal #1 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 pneumatic. g/ Fadal #2 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. h/ Fadal #3 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Inside of the Production Work Center 25 - CNC/CMM, periodic inspections of the specific procedures were not performed for the following machines: a/ Zimmerman FZ-35, NC 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. b/ SHODA NC-145 6-Axis Milling Machine, unlnown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. c/ Zimmerman FZ-30 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. d/ DMS #1 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. e/ DMS #2 5-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. f/ Fadal #1 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 pneumatic. g/ Fadal #2 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic. h/ Fadal #3 CNC 3-Axis Milling Machine, unknown m/n or s/n, 480 volts and 100 p.s.i. pneumatic.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a/ Inside of the Production Work Center 25 - CNC/CMM, lockout devices for the 480 volt and 100 p.s.i. pneumatic energy isolating devices were not affixed for the Zimmerman FZ-35, NC 5-Axis Milling Machine, unknown m/n or s/n, while its "head" was undergoing an alignment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a/ Inside of the Production Work Center 25-CNC/CMM, the chuck and unused portion of the bit belonging to the Bridgeport Milling Machine, s/n 68224, were unguarded.
Recent events (2)
- — I (O) $5000
- — Z (S) $5000
1910.212 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a/ Inside of the Production Work Center 25-CNC/CMM, the Bridgeport Milling Machine, s/n 68224, was not bolted to the concrete floor.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at LMI AEROSPACE INC.
COTTONWOOD FALLS, KS—2021-10-06 00:00:00
LMI AEROSPACE, INC
WASHINGTON, MO—2018-08-30 00:00:00
LMI AEROSPACE INC.
COTTONWOOD FALLS, KS—2018-02-08 00:00:00
LMI AEROSPACE, INC
View LMI AEROSPACE INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336413)
NORTH HOLLYWOOD, CA—2026-07-08
AVIBANK MANUFACTURING, INC
SALT LAKE CITY, UT—2026-07-08
NAMMO COMPOSITE SOLUTIONS
SALT LAKE CITY, UT—2026-07-02
BOEING COMPANY
TACOMA, WA—2026-07-01
WA317991845 - PRECISION MACHINE WORKS INC
FOLCROFT, PA—2026-06-30
ACE METAL INC.
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334598331.