SPRINGFIELD, IL —
OSHA Inspection: DESIGNED ROOFING SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DESIGNED ROOFING SYSTEMS, INC. in 3129 SOUTH VETERANS PARKWAY, SPRINGFIELD, IL 62704 (NAICS 236220). OSHA activity number 334603933.
Where did this inspection happen?
- Establishment
- DESIGNED ROOFING SYSTEMS, INC.
- Site address
- 3129 SOUTH VETERANS PARKWAY
- City
- SPRINGFIELD
- State
- IL
- ZIP
- 62704
- Mailing
- 4850 JEFFORY, SPRINGFIELD, IL 62707
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 29
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $3850.00 · Current $2695.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels was not fully planked or decked between the front uprights and the guardrail supports: Employees were exposed to a fall hazard of approximately 12 feet while working from a frame scaffold which was not fully planked between the uprights or guardrails.
Recent events (2)
- — I (S) $2695
- — Z (S) $3850
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: Employees were working from a frame scaffold which was not fully planked and the employer had not provided training to the employees on the hazards associated with working off of the scaffolding and procedures to minimize those hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 W02
- Issued
- Abate by
- Penalty
- Initial $3850.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(w)(2): Scaffold casters and wheels shall be locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold is used in a stationary manner: Employees were working from a frame scaffold and the scaffold casters and wheels were not locked to prevent movement of the scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $3850
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $3850.00 · Current $2695.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling: Employees were exposed to a fall hazard of approximately 12 feet because the frame scaffold did not have a top rail.
Recent events (2)
- — I (S) $2695
- — Z (S) $3850
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: Employees were working from a frame scaffold which was not erected or supervised under the direction of someone acting in the capacity of a competent person before employees were allowed to access the scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee who is involved in erecting, disassembling, moving, operation, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: Employees were working from a frame scaffold and the scaffold casters and wheels were not locked to prevent movement of the scaffold. The employer had not provided training to the employees on the nature of the scaffold hazards and the design criteria and the intended use of the scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at DESIGNED ROOFING SYSTEMS, INC.
SPRINGFIELD, IL—2016-11-01 00:00:00
DESIGNED ROOFING SYSTEMS, INC.
SPRINGFIELD, IL—2011-04-07 00:00:00
DESIGNED ROOFING SYSTEMS, INC.
SPRINGFIELD, IL—2009-10-29 00:00:00
DESIGNED ROOFING SYSTEMS, INC.
SPRINGFIELD, IL—2009-01-26 00:00:00
DESIGNED ROOFING SYSTEMS, INC.
ST JOSEPH, IL—2004-12-08 00:00:00
DESIGNED ROOFING SYSTEMS, INC.
View DESIGNED ROOFING SYSTEMS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
NEWPORT BEACH, CA—2026-07-16
KPRS CONSTRUCTION SERVICES, INC.
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
ROCHESTER HILLS, MI—2026-07-16
ICON RESTORATION SERVICES
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
PONCE, PR—2026-07-15
FC CONSTRUCTION LLC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334603933.