NEWTON, KS —
OSHA Inspection: MID-CONTINENT CABINETRY, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MID-CONTINENT CABINETRY, LLC in 900 S. MERIDIAN RD, NEWTON, KS 67114 (NAICS 337110). OSHA activity number 334653003.
Where did this inspection happen?
- Establishment
- MID-CONTINENT CABINETRY, LLC
- Site address
- 900 S. MERIDIAN RD
- City
- NEWTON
- State
- KS
- ZIP
- 67114
- Mailing
- 900 S. MERIDIAN RD, NEWTON, KS 67114
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 387
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $2380.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At 900 S. Meridian Rd, Newton, KS in the maintenance building, the Enco Band saw was missing point of operation guarding on the left and right side of the 1" blade exposure, exposing employees to an amputation hazard.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $2380.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. At the building three entrance, an energized electrical receptacle has a broken, lower outlet with exposed electrical contacts, exposing employees to electrical shock.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.303 B08 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it was mounted At the building three entrance, an energized electrical receptacle was not secured to the outlet box, exposing employees to electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 I
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners: At 900 S. Meridian Rd, Newton, KS, in Building 3 in the Edge Banding area, a seven-outlet power strip was plugged into a 25 feet extension cord. The power strip was being used to power a box fan, exposing employees to a potential fire hazard.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1910.333 A02
- Issued
- Penalty
- Initial $3400.00 · Current $2380.00 Reduced
General-duty citation text
29 CFR 1910.333(a)(2): Where exposed live parts were not deenergized, other safety related work practices were not used to protect employees who could be exposed to the electrical hazards involved: At 900 S. Meridian Rd, Newton, KS in the Edge Banding Area, the Holzma Panel Saw electrical control panel door latch was defective, leaving the door open, exposing employees to a shock hazard from the 460 VAC equipment contained inside the enclosure.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): In Building 1, the Viet Wide Belt Sander Lockout/Tagout procedures were inadequate for the control of hazardous energy in that the procedures developed did not correctly identify the electrical disconnect on the front of the machine as the proper lockout/tagout location, nor did the procedures address the control of the pneumatic energy on the equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 337110)
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
ORLANDO, FL—2026-07-15
ROSTOV, LLC
RICHMOND HILL, GA—2026-07-14
WILSON CABINETRY, LLC
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
More inspections in KS
SHAWNEE, KS—2026-07-15
BECKER EXTERIORS
SHAWNEE, KS—2026-07-15
DLR RENOVATION
SHAWNEE, KS—2026-07-15
LUIS ARIAS
OLATHE, KS—2026-07-15
U.S. POSTAL SERVICE
ARKANSAS CITY, KS—2026-07-15
SKYLINE HOMES
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334653003.