Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SUPERIOR EXTERIOR HOME IMPROVEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUPERIOR EXTERIOR HOME IMPROVEMENT in 258 FORTEENTH STREET, BANGOR, ME 04401 (NAICS 238170). OSHA activity number 334731981.

Watch Superior Exterior Home Improvement — free Get an email when a new federal OSHA severe-injury report for Superior Exterior Home Improvement is published. One employer, no account, unsubscribe in one click.
Site address
258 FORTEENTH STREET
City
BANGOR
State
ME
ZIP
04401
Mailing
8 GREEN STREET, WEST ENFIELD, ME 04493
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
1
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $700.00 Reduced
29 CFR 1926.100(a):     Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.    Residential Building - The employee working below the pump jack scaffold was not wearing a hard hat.
Recent events (2)
  • — I (S) $700
  • — Z (S) $1200

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.451(g)(1):     Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level.  Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold.    Residential Building - The employee on the pump jack scaffold 11 feet above the ground was not protected from falling.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.452 J02

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $700.00 Reduced
29 CFR 1926.452(j)(2):     Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    Residential Building - The pump jack scaffold was not equipped with a bottom brace.
Recent events (2)
  • — I (S) $700
  • — Z (S) $1200

1926.451 C02

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.    Residential Building - The wooden poles on the pump jack scaffold did not bear on base plates or mud sills.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334731981.