BANGOR, ME —
OSHA Inspection: SUPERIOR EXTERIOR HOME IMPROVEMENT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUPERIOR EXTERIOR HOME IMPROVEMENT in 258 FORTEENTH STREET, BANGOR, ME 04401 (NAICS 238170). OSHA activity number 334731981.
Where did this inspection happen?
- Establishment
- SUPERIOR EXTERIOR HOME IMPROVEMENT
- Site address
- 258 FORTEENTH STREET
- City
- BANGOR
- State
- ME
- ZIP
- 04401
- Mailing
- 8 GREEN STREET, WEST ENFIELD, ME 04493
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 1
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. Residential Building - The employee working below the pump jack scaffold was not wearing a hard hat.
Recent events (2)
- — I (S) $700
- — Z (S) $1200
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Residential Building - The employee on the pump jack scaffold 11 feet above the ground was not protected from falling.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. Residential Building - The pump jack scaffold was not equipped with a bottom brace.
Recent events (2)
- — I (S) $700
- — Z (S) $1200
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. Residential Building - The wooden poles on the pump jack scaffold did not bear on base plates or mud sills.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in ME
AUGUSTA, ME—2026-07-14
JJ GONZALEZ ROOFING AND GUTTERS
DOVER FOXCROFT, ME—2026-07-14
REDI-ROCK OF CENTRAL MAINE
PORTLAND, ME—2026-07-06
NEW ENGLAND REHABILITATION HOSPITAL OF PORTLAND
DOVER FOXCROFT, ME—2026-07-06
SHAW'S SUPERMARKETS
GORHAM, ME—2026-07-02
TOWN OF GORHAM
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334731981.