OSHA Inspection: FOREN CONSTRUCTION CO. INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOREN CONSTRUCTION CO. INC. in 444-448 TERRACE AVENUE, HASBROUCK HEIGHTS, NJ 07604 (NAICS 238140). OSHA activity number 334771599.

Watch Foren Construction CO. INC. — free Get an email when a new federal OSHA severe-injury report for Foren Construction CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
444-448 TERRACE AVENUE
City
HASBROUCK HEIGHTS
State
NJ
ZIP
07604
Mailing
38 LAFAYETTE AVENUE, CLIFFSIDE PARK, NJ 07010
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.95 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1760.00 · Current $704.00 Reduced
29 CFR 1926.95(a):     Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    a)  Rear Wall Area:  The ground worker assisting the workers on the raised suspended scaffold was not wearing any head protection, on or about 6/20/2012.
Recent events (2)
  • — I (S) $704
  • — Z (S) $1760

1926.451 H02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(h)(2)(ii):     A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:  Note:  This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toeboards.    a)  Rear Wall Area:  The two point suspended scaffold platform did not have any toeboard or any screening installed at the platform edge, on or about 6/20/2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 D05 III

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $2200.00 · Current $880.00 Reduced
29 CFR 1926.451(d)(5)(iii):     Suspension scaffold support devices such as cornice hooks, roof hooks, roof irons, parapet clamps, or similar devices were not secured against movement by tiebacks installed at right angles to the face of the building or structure, and were not secured to a structurally sound point of anchorage on the building or structure:    a)  Roof:  The two point suspended scaffold roof hooks had tiebacks that were tied to the building's plumbing vent pipes, on or about 6/20/2012.    b)  Roof:  The two point suspended scaffold roof hooks had single tiebacks installed at an angle, on or about 6/20/2012.     Abatement note:  Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit.
Recent events (2)
  • — I (S) $880
  • — Z (S) $2200

1926.451 G03

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $3080.00 · Current $1232.00 Reduced
29 CFR 1926.451(g)(3):  Personal fall arrest systems used on scaffolds were not attached by lanyard to a vertical life line:    a)  Rear wall area:  Two personal fall arrest system harness lanyards were attached to the vertical life line by knot.  A rope grab was not used for the lifeline/lanyard connections, on or about 6/20/2012.
Recent events (2)
  • — I (S) $1232
  • — Z (S) $3080

1926.451 G03 I

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(3)(i):     Verical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion.  a)  Roof:  The lifelines used by the workers on the suspension scaffold were attached to a tree branch, and the were not protected form the roof edges, on or about 6/20/2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View FOREN CONSTRUCTION CO. INC.'s full OSHA safety record →