OSHA Inspection: PHOENIX METALWORKS, L.P.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PHOENIX METALWORKS, L.P. in 1135 DUNLAVY ROAD, CAT SPRING, TX 78933 (NAICS 332999). OSHA activity number 334814183.

Watch Phoenix Metalworks, L.P. — free Get an email when a new federal OSHA severe-injury report for Phoenix Metalworks, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
1135 DUNLAVY ROAD
City
CAT SPRING
State
TX
ZIP
78933
Mailing
1135 DUNLAVY ROAD, CAT SPRING, TX 78933
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
10
Ownership type
A

19 citations on file for this inspection.

1910.151 B

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.151(b):   There was neither an infirmary, clinic, or hospital used for the treatment of all injured employees in near proximity to the workplace nor a person or persons adequately trained to render first aid:  On or about June 08, 2012, and at times prior thereto, the employer did not ensure that a perosn or persons were trainied to render first aid in the event of a medical emergency, exposing the employees within the facility to delayed medical treatment.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.157 C01

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.157(c)(1):   The employer did not provide portable fire extinguishers and did not mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.  For work performed within the facility: On or about June 08, 2012, and at times proir thereto, the employer did not ensure that portable fire extinguishers in two instances were mounted, and identified so that they were readily accessible.   Instance a) In the Press Break area a fire extinguisher was located next to the press break on the floor, the extinguisher dial indicated it was discharged.   Instance b) In the planer department a fire extinguisher was located on a table loacated in the southeast corner of the room, the fire extinguisher dial indicated it was discharged.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.157 C04

Serious Gravity 5 3 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(4):   Portable fire extinguishers were not maintained in a fully charged and operable condition:  On or about June 08, 2012, and at times prior thereto, fire extinguishers were found missing or needing to be recharged as follows:  Instance a) In the Planer Department, The fire extinguisher was not fully charged. The dial indicator presented that the fire extinguisher needed to be recharged.  Instance b) In the Buffer and Shipping Department, The fire extinguisher was not fully charged. The dial indicator presented that the fire extinguisher needed to be recharged.  Instance c) In the Press Break Department, The fire extinguisher was not fully charged. The dial indicator presented that the fire extinguisher needed to be recharged.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E02

Serious Gravity 5 3 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2):   Portable fire extinguishers were not visually inspected at least monthly:  On or about June 08, 2012, and at times prior thereto, the fire extinguishers throughout the facility were not visually inspected monthly.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.178(l)(1)(i):   The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about June 08, 2012, and at times prior thereto, the employer did not ensure that each employee operating a power industrial truck had succesfully completed a training and evaluation progrm prior to being allowed to operate the Hyundai Model #HLF25-5 Power Industrail Truck.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.212 A01

Serious Gravity 10 6 instances 10 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.212(a)(1):   One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about June 08, 2012, and at times prior thereto, the employer did not provide machine guards in six instances within the facility, exposing the employee to the hazards created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.   Instance a) In the Planer Department the horizontal table on the white Rockford Planer was not guarded to prevent employees from being caught between the table and adjacent structures.   Instance b) In the Planer Department the horizontal table on the green Rockford Planer was not guarded to prevent employees from being caught between the table and adjacent structures.  Instance c) In the Buffer and Shipping Department the Pedestal, Electronic, Variable Speed Buffer and Polisher did not have guards installed over the 18 inch buffing pads.   Instance d). In the Buffer and Shipping Department the Jet 10" Buffer/Sander Model# JSB-10H did not have guards installed over the 10 Inch buffing pads.   Instance e) In the Press Break area the blue Alantic Machine Tools Press Break, Model HDC was not equipped with machine guards to prevent employees' hands from being caught in the machine.   Instance f) In the Press Break area the grey Haco Machine Tools Press Break was not equipped with machine guards to prevent employees' hands from being caught in the machine.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.212 B

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.212(b):     Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  On or about June 08, 2012, and at times prior thereto, the employer did not ensure that the pedistal buffer/polisher located in the buffing and shipping department was anchored to the ground to prevent walking or moving, exposing the employee operating the buffer/polisher to the hazards of being struck by the machine or work piece.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.213 C01

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $960.00 Reduced
29 CFR 1910.213(c)(1):     Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  On or about June 08, 2012, and at times prior thereto, employees were exposed to the hazards of being struck by the saw blade, flying debris or broken saw blade fragments while operating a Rockwell Tilting Arbor Table Saw without a blade guard.
Recent events (2)
  • — I (S) $960
  • — Z (S) $2800

1910.213 C02

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(2):   Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:  On or about June 08, 2012 and at times prior thereto, employees were exposed to the hazards associated with the saw jamming, including flying debris and ejected material thrown at the operator while operating the Rockford Tilting Arbor Table Saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(3):     Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  On or about June 08, 2012, and at times prior thereto, employees were exposed to the kick back of work material while operating a table saw without a non-kickback device installed on it.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 I01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.213(i)(1):     All portions of the saw blade were not enclosed or guarded, except for the working portion of the blade between the bottom of the guide rolls and the table. Bandsaw wheels were not fully encased. The front and back of the band wheels were not either enclosed by solid material or by wire mesh or perforated metal. Such mesh or perforated metal was not not less than 0.037 inch (U.S. Gage No. 20), and the openings were greater than three-eighths inch. The guard for the portion of the blade between the sliding guide and the upper-saw-wheel guard did not protect the saw blade at the front and outer side.  On or about June 08, 2012, and at times prior thereto, the Delta Band Saw located in the shipping department did not have guards installed over the non-working portion of the blade and the band saw's wheels were not fully encased with solid material or by wire mesh or perforated metal.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.242 B

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.242(b):   Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On or about June 08, 2012, and at times prior thereto, air nozzles were routinely used for cleaning at compressed air pressures up to 60 psig. One air nozzle located in press break department was found exceeding the pressure of 30 psig and lacking safety relief holes in the nozzle tip.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.303 G02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) On or about June 08, 2012, and at times prior thereto, the employer did not ensure that the power control panel on the Green Rockford Planer in the planer department operating at 50 volts or more was guarded against accidental contact by approved cabinets or other approved enclosures, exposing employees operating the planer to electrical hazards.    b) On or about June 08, 2012, and at times prior thereto, in the corner of the planer department a breaker box had missing breakers, creating access to live parts.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 B01 II

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:  On or about June 08, 2012, and at times prior thereto, in the planer department, open knockout slug on the side of the breaker box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 X

Serious Gravity 5 3 instances 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.305(a)(2)(x):     Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.  On or about June 08, 2012, and at times prior thereto, the employer did not ensure that fexiable cords or cables were protected from accidental damage in 3 instances, exposing employees to electrical hazards.     Instance a) In the Planer Department the Red 25 Foot extension cords was damaged and had exposed copper wires.     Instance b) In the Planer Departement on the power control panel, the yellow flexable cables leading from the control box to the machines were not protected by conduit.     Instance c) In the Buffing and Shipping Department, a red and an orange cable were damaged and had the inner sheathing showing.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 G02 III

Serious Gravity 5 4 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii):     Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On or about June 08, 2012, and at times prior thereto, there were four instances of flexible cords used in the facility and were found with the outer insulation pulled away from the plugs strain relief, exposing the employee to electrical hazards.     Instance a) In the Planer Department on the Green Rockford Planer's power control box, the power supply cables at the top of the box were not installed so that tension was not permitted on the electical connections.     Instance b) In the Shipping Department the Rockford Table Saw power control box power supply cable's outer insulation was pulled away from the cable's strain relief.    Instance c) In the Buffing and Shipping Department the red 25 foot extension cord had the outer insulation pulled away from the cable's strain relief.     Instance d) In the Press Break Department, both press break foot pedals had the outer insulation pulled away from the cables' strain relief.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 6 instances 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $960.00 Reduced
29 CFR 1910.305(b)(2)(i):     Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose and each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    On or about June 08, 2012, and at times prior thereto, the employer did not enusre in six instances that all outlet boxes and switch boxes installed in the facility had covers, faceplates or a fixture canopy intalled on them, exposing employees to electrical hazards.     Instance a) In the Planer Department on the east side wall next to the planer control box, a 240 volt outlet was missing the cover.     Instance b) In the Buffing and Shipping Department on the center wall a 110 volt electrical outlet box was missing the cover.     Instance c) In the Buffing and Shipping Department on the center wall a 240 volt electrical outlet box was missing the cover.     Instance d) In the Buffing and Shipping Department on the center was a double light switch box was missing the cover.     Instance e) In the Buffing and Shipping Department on the center wall a second 110 volt electrical outlet box was missing the cover.     Instance f) In the Press Break Department next to the blue press break on the support beam a single light switch box was missing the cover.
Recent events (2)
  • — I (S) $960
  • — Z (S) $2000

1910.219 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.219(d)(1):  Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about June 8, 2012 and in times prior thereto, the belt and pulleys on the Delta Bandsaw were not guarded.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.219 E03 I

Serious Gravity 5 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(3)(i):  Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):    On or about June 8, 2012, and in times prior thereto, the belt and pulleys on the Delta Bandsaw were not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334814183.