OSHA Inspection: JESUS RESENDIZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JESUS RESENDIZ in 1003 HIGHWAY 288, FREEPORT, TX 77542 (NAICS 238140). OSHA activity number 334816584.

Watch Jesus Resendiz — free Get an email when a new federal OSHA severe-injury report for Jesus Resendiz is published. One employer, no account, unsubscribe in one click.
Establishment
JESUS RESENDIZ
Site address
1003 HIGHWAY 288
City
FREEPORT
State
TX
ZIP
77542
Mailing
215 STROTTON RIDGE #43, CLUTE, TX 77531
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)    At the site, employees were using one scaffold lumber plank per vertical section of tubular welded frame scaffold as means for moving between sections.
Recent events (1)
  • — Z (S) $2400

1926.451 C02

Serious Gravity 5 10 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:    At the site, where tubular welded frame scaffold was being used by employees to perform stucco work without any base plates.
Recent events (1)
  • — Z (S) $1600

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    At the site, employees used the tubular welded frame scaffold crossbraces and bearers for access and egress to thier working levels
Recent events (1)
  • — Z (S) $1600

1926.452 C02

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.452(c)(2):     Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:    At the site, cross braces were missing from horizontal sections of the scaffold while employees were occupying the platforms and exposed to fall hazards.
Recent events (1)
  • — Z (S) $1600