SARATOGA SPRINGS, NY —
OSHA Inspection: PRECAST SERVICES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PRECAST SERVICES, INC. in WOODLAWN PARKING GARAGE, SARATOGA SPRINGS, NY 12866 (NAICS 238120). OSHA activity number 334843380.
Where did this inspection happen?
- Establishment
- PRECAST SERVICES, INC.
- Site address
- WOODLAWN PARKING GARAGE
- City
- SARATOGA SPRINGS
- State
- NY
- ZIP
- 12866
- Mailing
- 8200 BOYLE PARKWAY, TWINSBURG, OH 44087
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 95
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.21 B02
- Issued
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: (a) First Story Floor, prior to removal of temporary support bracing, on or about June 21, 2012 - the employer did not adequately instruct employees in the safe removal of brace rod(s), including but not limited to: location or identification of brace rod(s) which should not be removed.
Recent events (3)
- — F (O) $0
- — C (S) $4900
- — Z (S) $4900
1926.704 A
- Issued
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.704(a): Precast concrete wall units, structural framing and tilt-up wall panels were not adequately supported to prevent overturning and to prevent collapse until permanent connections were completed: (a) First Story Floor, between Column Lines 4 & 5, A & B, on or about June 21, 2012 - The upper concrete spandrel panel was not adequately supported, in that: permanent connections were not completed prior to removal of support brace(s).
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
More inspections at PRECAST SERVICES, INC.
PHILADELPHIA, PA—2026-04-08
PRECAST SERVICES INC
ALBANY, NY—2025-01-27
PRECAST SERVICES INC
CARLISLE, PA—2020-08-28 00:00:00
PRECAST SERVICES INC.
LANSING, MI—2015-11-03 00:00:00
PRECAST SERVICES INC.
BUFFALO, NY—2015-04-30 00:00:00
PRECAST SERVICES, INC.
View PRECAST SERVICES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
MIDLOTHIAN, VA—2026-07-09
B & J STEEL CONSTRUCTION, INC.
LYNCHBURG, VA—2026-07-09
GRAY'S WELDING LLC
CHESAPEAKE, VA—2026-07-08
MODERN STEEL AND STAIR LLC
YAKIMA, WA—2026-07-07
WA317991949 - H & A STEEL ERECTORS LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334843380.