Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOHNSON OUTDOOR WATERCRAFT, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOHNSON OUTDOOR WATERCRAFT, INC. in 125 GILMAN FALLS AVENUE, BUILDING B, OLD TOWN, ME 04468 (NAICS 336612). OSHA activity number 334903184.

Watch Johnson Outdoor Watercraft, INC. — free Get an email when a new federal OSHA severe-injury report for Johnson Outdoor Watercraft, INC. is published. One employer, no account, unsubscribe in one click.
Site address
125 GILMAN FALLS AVENUE, BUILDING B
City
OLD TOWN
State
ME
ZIP
04468
Mailing
125 GILMAN FALLS AVENUE, BUILDING B, OLD TOWN, ME 04468
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
200
Ownership type
A

6 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 11 instances 25 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $2100.00 Reduced
29 CFR 1910.22(d)(1):     On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.    Building B, Receiving Area - The employer did not have a structural load rating posted on the eleven storage racks.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3750.00 · Current $2625.00 Reduced
29 CFR 1910.23(c)(1):     Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:      Oven #6, Loading Station - An employee was exposed to a five foot fall when he did not use the provided safety chain.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3750

1910.37 B04

Serious Gravity 5 8 instances 25 exposed
Issued
Abate by
Penalty
Initial $3750.00 · Current $2625.00 Reduced
29 CFR 1910.37(b)(4):     If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times.      Building B - The direction of travel to the eight emergency exit doors were not clearly visble at all times.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3750

1910.213 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $2100.00 Reduced
29 CFR 1910.213(b)(3):     On applications where injury to the operator might result if motors were to restart after power failures, provision shall be made to prevent machines from automatically restarting upon restoration of power.      Building A, Back of Retail Store -  Employees were operating a Craftsman table saw that did not have an anti-restart safety device.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.253 B04 III

Other-than-serious 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(4)(iii):     Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.      Building A, Receiving Area #2 and #3 - A cylinder of oxygen was stored five feet from a cylinder of acetylene.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii):     Unused openings in cabinets, boxes, and fittings shall be effectively closed.    Building A, Back of Retail Store - The following electrical breaker panels were missing the a front cover screw:    1. Panel #2P.  2. Panel #3P.