Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: CHAMPS MANAGEMENT, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHAMPS MANAGEMENT, LLC in 4480 ALUM CREEK DR., COLUMBUS, OH 43207 (NAICS 722211). OSHA activity number 334911088.

Watch Champs Management, LLC — free Get an email when a new federal OSHA severe-injury report for Champs Management, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4480 ALUM CREEK DR.
City
COLUMBUS
State
OH
ZIP
43207
Mailing
8414 STATE ROUTE 124, HILLSBORO, OH 45133
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722211
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced
29 CFR 1910.147(c)(1):     Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    a. At the Champs Property Management facility located on Alum Creek Dr. in Columbus, Ohio, the employer had not developed an energy control program for the employees that would service equipment at the facility.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.305 G01 IV B

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1620.00 Reduced
29 CFR 1910.305(g)(1)(iv)(B):     Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:    Where run through holes in walls, ceilings, or floors;    a. At the Champs Property Management facility located on Alum Creek Dr. in Columbus, Ohio, the employer had a wall mounted light that had its cord run up through a ceiling tile, and then back down through the same tile, and then plugged into a receptacle outlet that was mounted on the ceiling.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700