WEATHERFORD, OK —
OSHA Inspection: WILDCAT MINERALS LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WILDCAT MINERALS LLC in 111 EAST EADS, WEATHERFORD, OK 73096 (NAICS 423840). OSHA activity number 335266201.
Where did this inspection happen?
- Establishment
- WILDCAT MINERALS LLC
- Site address
- 111 EAST EADS
- City
- WEATHERFORD
- State
- OK
- ZIP
- 73096
- Mailing
- 111 EAST EADS, WEATHERFORD, OK 73096
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423840
- Employees
- 9
- Ownership type
- A
Citations
22 citations on file for this inspection.
1910.106 E06 I
- Issued
- Abate by
- Penalty
- Initial $2601.00 · Current $1561.00 Reduced
1340
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: a. On or about 7/16/2012, Terminal Yard, The area around a 100 gallon capacity portable gasoline tank was not posted with a No Smoking sign where employees fuel equipment with gasoline which exposes employees to fire hazards.
Recent events (2)
- — I (S) $1560.6
- — Z (S) $2601
1910.141 A04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(a)(4)(i): Receptacle(s) used for putrescible solid or liquid waste or refuse were not equipped with tight fitting cover(s) necessary to maintain sanitary conditions: a. On or about 7/16/2012, Terminal Yard, 2 waste containers for spent oil and 4 waste containers for spent hydraulic fluid did not have covers which exposes employees to fire and chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: a. On or about 7/16/2012, Terminal Scale Office, Two portable fire extinguishers were not fully charged and employees fueled equipment with diesel and gasoline which exposes employees to fire hazards. b. On or about 7/16/2012, Terminal Storage Room, A portable fire extinguisher was not fully charged where an acetylene cylinder and a compressed oxygen cylinder were attached to a welding torch which exposes employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a. On or about 7/16/2012, Terminal, Annual portable fire extinguisher training was not provided to employees expected to use portable fire extinguishers where diesel, gasoline, compressed oxygen, and acetylene were present which exposes employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 A02
- Issued
- Abate by
- Penalty
- Initial $3825.00 · Current $2295.00 Reduced
9010
General-duty citation text
29 CFR 1910.134(a)(2): A respirator was not provided by the employer to each employee when such equipment was necessary to protect the health of the employee: a. On or about 7/17/2012, Terminal, The employer did not provide a respirator to a transloader operator to use when loading resin sand and/or raw sand from railcars to sand truck trailers, and from a sand truck trailer to a sand truck trailer which exposes the employee to Crystalline Silica, Quartz.
Recent events (2)
- — I (S) $2295
- — Z (S) $3825
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9010
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. On or about 7/17/2012, Terminal, A written respiratory protection program with work-site specific procedures was not developed and implemented for a transloader employee who loads resin sand and raw sand from railcars to sand truck trailers, and from sand truck trailer to sand truck trailer which exposes the employee to Crystalline Silica, Quartz.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1000 C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9010
General-duty citation text
29 CFR 1910.1000(c): An employee(s) was exposed to Silica Crystalline Quartz (Respirable) in excess of the 8-hour time weighted average limits listed in Table Z-3: a. On or about 7/17/2012, Terminal, An employee personal 8-hour time-weighted average (8-Hr TWA) exposure to respirable dust containing 53% Crystalline Silica Quartz was 0.46 mg/m3 during trans-loading of resin sand and raw sand from railcars to sand truck trailers and from sand truck trailers to sand truck trailers. This exposure exceeded the OSHA 8-Hr TWA Crystalline Silica Quartz PEL of 0.182 mg/m3 by 2.4 times for respirable dust containing 53% Crystalline Silica Quartz. The personal air monitoring consisted of one sample collected during a 455 minute sampling period on 7/17/2012. The remaining un-sampled time of 25 minutes was included in the 8-Hr TWA as a zero exposure period.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1000 E
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9010
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a. On or about 7/17/2012, Terminal, Transloader operators were exposed to crystalline silica and administrative or engineering controls were not first determined and implemented for railcar to sand truck trailer, and sand truck trailer to sand truck trailer transloading of resin and raw sand which includes but is not limited to the following: 1. Limit sand loading amounts to transloaders to prevent sand jams 2. Use of long handled tools to clear sand jams from transloader conveyor belts 3. Prompt cleanup of sand piles in transloading areas 4. Installation of a cover on a balancer of a transloader
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 A04 II
- Issued
- Abate by
- Penalty
- Initial $1951.00 · Current $1171.00 Reduced
General-duty citation text
29 CFR 1910.141(a)(4)(ii): Wastes were not removed as often as necessary to maintain the place of employment in a sanitary condition: a. On or about 7/16/2012, Terminal, A chemical toilet was not timely serviced to ensure deodorizing chemicals were effective which exposes employees to health hazards and unsanitary conditions.
Recent events (2)
- — I (S) $1170.6
- — Z (S) $1951
1910.141 C01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(c)(1)(i): Toilet facilities were not provided in accordance with TABLE J-1 of this Section: a. On or about 7/16/12, Terminal, A water closet was not provided in the fixed location workplace which exposes employee to health hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 D02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(d)(2)(i): Lavatory(s) were not made available: a. On or about 7/16/2012, Terminal, A lavatory equipped with hot and cold running water, a hand cleansing agent, and hand drying was not available in the fixed location worksite which exposes employees to health hazards and unsanitary conditions.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C05 I
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: a. On or about 7/16/12, Terminal, Lockout tagout devices were not provided by the employer for isolating, securing, or blocking equipment such as transloaders from energy sources.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a. On or about 7/16/12, Terminal, The employer did not provide hazardous energy control (lockout tagout) training to employees who performed maintenance and who operated equipment which included but was not limited to transloader machines.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about 7/16/2012, Terminal Yard, Transloader SN 5240 did not have a cover at its balancer which was comprised of a rotating shaft and two discs and exposes employees caught-by hazards from rotating parts.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a. On or about 7/16/2012, Terminal Yard, The drive axle sprocket and chain and the steering drive chain and sprocket that were less than 7 feet from the ground, were not enclosed on the following transloaders, exposing employees who worked with transloaders to in-going nip point hazards: 1. Transloader Model TL 1215 (diesel powered), SN 5240 2. Transloader Model TL 1215 (diesel powered), SN 5136
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about 7/16/2012, Terminal Yard, A receptacle marked 30A-250V that was placed on the ground was not installed and used according to its labeling and listing which exposes employees to electric shock hazards.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.304 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(b)(4): Outlet devices had an ampere rating less than the load being served a. On or about 7/16/2012, Terminal Yard, A receptacle marked 30A-250V was used to power a 47.5 amp welder which exposes employees to electric shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 J02 VII
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed: a. On or about 7/16/2012, Terminal Yard, A 250 volt receptacle installed at an outside wall did not have an enclosure that provides a weatherproof cover when an attachment plug of an electric cable is removed and this exposes employees to electric shock hazards when using the receptacle to power a welder.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01 I
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet: a. On or about 7/16/2012, Terminal, A list of the hazardous chemicals known to be present using an identity referenced on the material safety data sheet was not developed and maintained which included but was not limited to the following: 1. Diesel Fuel (combustible liquid) 2. Gasoline (flammable liquid) 3. Acetylene (flammable liquid) 4. Compressed Oxygen (oxidizer) 5. Resin Coated Silica Sand (irritant) 6. Lake or Bank Sand (irritant) 7. Hydraulic fluid (irritant)
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.1200 F05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a. On or about 7/16/2012, Terminal Yard, A portable gasoline tank and a portable diesel tank did not have identity labels and this condition exposes employees to flammable, combustible, and chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a. On or about 7/16/2012, Terminal Yard, A portable gasoline tank and a portable diesel tank did not have hazard warning labels and this condition exposes employees to flammable, combustible, and chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a. On or about 7/16/2012, Terminal, The employer did not have material safety data sheets in the workplace for hazardous chemicals which included but was not limited to the following: 1. Diesel Fuel (combustible liquid) 2. Gasoline (flammable liquid) 3. Acetylene (flammable liquid) 4. Compressed Oxygen (oxidizer)
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at WILDCAT MINERALS LLC
BRUSH, CO—2014-04-29 00:00:00
WILDCAT MINERALS, LLC
View WILDCAT MINERALS LLC's full OSHA safety record →
More inspections in this industry (NAICS 423840)
LIVERMORE, CA—2026-07-16
RJMS CORPORATION
WICHITA, KS—2026-07-08
IBT, INC
HOUSTON, TX—2026-06-24
FASGO INC.
INDEPENDENCE, KY—2026-06-18
69237 - TRISTATE VALVES - CONTROLS INC
CARLISLE, PA—2026-06-12
APPLIED INDUSTRIAL TECHNOLOGIES
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335266201.