Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENGINEERED RESTORATIONS, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ENGINEERED RESTORATIONS, INC in 201 WEST PONCE DE LEON AVE, DECATUR, GA 30005 (NAICS 236220). OSHA activity number 335266656.

Watch Engineered Restorations, INC — free Get an email when a new federal OSHA severe-injury report for Engineered Restorations, INC is published. One employer, no account, unsubscribe in one click.
Site address
201 WEST PONCE DE LEON AVE
City
DECATUR
State
GA
ZIP
30005
Mailing
225 BUFORD DRIVE, LAWRENCEVILLE, GA 30046
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
70
Ownership type
A

1 citation on file for this inspection.

1926.451 C01 II

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $5390.00 · Current $5390.00
29 CFR 1926.451(c)(1)(ii):  Guys, ties, and/or braces were not installed  according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide.    On or about7/18/12 at 201 West Ponce De Leon Av Decatur, GA:  The employer did not ensure that the 65' x  44' scaffolding on which the employees were performing water proofing work on, had been tied-into the building.
Recent events (2)
  • — I (O) $5390
  • — Z (S) $5390

View ENGINEERED RESTORATIONS, INC's full OSHA safety record →