Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WILCOX TRUCK LINE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILCOX TRUCK LINE, INC. in 438 NORTH NETTLETON AVENUE, SPRINGFIELD, MO 65802 (NAICS 484110). OSHA activity number 335312989.

Watch Wilcox Truck Line, INC. — free Get an email when a new federal OSHA severe-injury report for Wilcox Truck Line, INC. is published. One employer, no account, unsubscribe in one click.
Site address
438 NORTH NETTLETON AVENUE
City
SPRINGFIELD
State
MO
ZIP
65802
Mailing
P.O. BOX 3325, SPRINGFIELD, MO 65808
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484110
Employees
106
Ownership type
A

3 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2520.00 Reduced
29 CFR 1910.215(a)(4):     Grinding machinery was not used with work rest(s) to support offhand grinding work:        (a)  The bench grinder on the mechanic's workbench was not provided with a tool rest to support grinding of tools.        Abatement verification is required for this item.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $3600

1910.304 G05

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $4410.00 Reduced
29 CFR 1910.304(g)(5):     The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:      (a)  The path to ground of the receptacle on the west wall of the truck repair bay was not continueous.          When tested, the receptacle showed that the circuit was not grounded.       (b)  The path to ground on the receptacle next to the passage door on the northwest corner of the shop          was not continueous.  When tested the receptacle showed that the receptacle was not grounded.  This         receptacle is used daily by the truck mechanic.      Abatement verification is required for this item.
Recent events (2)
  • — I (S) $4410
  • — Z (S) $6300

1910.305 A02 X

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2520.00 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage:    (a)  The power cord to the Milwaukee Cut off Saw on the north west wall of the truck repair bay was         not protected from damage.  There were three sections of the power cord where insulated conductors         were exposed.      (a)  Abatement verification is required for this item.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $3600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335312989.