BRIDGETON, NJ —
OSHA Inspection: BRIDGETON PLUMBING & HEATING SUPPLY CO.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BRIDGETON PLUMBING & HEATING SUPPLY CO. in 756 NORTH PEARL STREET, BRIDGETON, NJ 08302 (NAICS 493190). OSHA activity number 335326385.
Where did this inspection happen?
- Establishment
- BRIDGETON PLUMBING & HEATING SUPPLY CO.
- Site address
- 756 NORTH PEARL STREET
- City
- BRIDGETON
- State
- NJ
- ZIP
- 08302
- Mailing
- 756 NORTH PEARL STREET, BRIDGETON, NJ 08302
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493190
- Employees
- 18
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.157 G01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting: (a) Facility: Training was not provided to employees on the use of the portable fire extinguishers and the hazards associated with fighting and incipient stage fire, occurred on or about 7/20/12. BY THIS DATE THE EMPLOYER MUST EITHER CORRECT THE ALLEGED VIOLATION(S) OR IMPLEMENT A FIRE SAFETY POLICY, AS OUTLINED IN 29 CFR 1910.38 WHICH INCLUDES THE EVACUATION REQUIREMENTS OF 29 CFR 1910.157(b). NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l) (a) Facility: The employer failed to provide powered industrial truck training to each employee who operated a lift, occurred on or about, 7/20/12. 29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) Facility, Warehouse: Daily inspections were not performed on the Hyster forklift, occurred on or about 7/20/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
More inspections in this industry (NAICS 493190)
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
SANTA ANA, CA—2026-07-09
NGY GROUP (ORANGE COUNTY) INC.
CHICAGO, IL—2026-07-06
CHICAGO FURNITURE & MATTRESS WAREHOUSE DBA ULTIMATE FURNITURE & MATTRESS, INC.
GRESHAM, OR—2026-07-02
317744737 - VASCO SERVICES LLC
LINDON, UT—2026-06-29
SILHOUETTE AMERICA, INC.
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.