Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JDR WILLIAMS, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of JDR WILLIAMS, LLC in 360 EAST AVENUE, ROCHESTER, NY 14624 (NAICS 236220). OSHA activity number 335353181.

Watch JDR Williams, LLC — free Get an email when a new federal OSHA severe-injury report for JDR Williams, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JDR WILLIAMS, LLC
Site address
360 EAST AVENUE
City
ROCHESTER
State
NY
ZIP
14624
Mailing
797 GILMORE ROAD, BROCKPORT, NY 14420
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.300 B06

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.300(b)(6):     "Anchoring fixed machinery." Machines designed for a fixed location shall be securely anchored to prevent walking or moving.    On or about 07/20/12, on 360 East Avenue, in Rochester, New York, a mitre saw was in use while not anchored or secured in place.    NO ABATEMENT  CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.403 I02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $720.00 Reduced
29 CFR 1926.403(i)(2)(i):     Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact:        On or about 07/20/12,  on 360 East Avenue, in Rochester, New York, live electrical wiring was not protected against accidental contact    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $720
  • — Z (S) $1600

1926.405 J01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1926.405(j)(1)(ii):     Support. Fixtures, lampholders, rosettes, and receptacles shall be securely supported.     On or about 07/20/12, on 360 East Avenue, in Rochester, New York, receptacles in use were not anchored or secured in place.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335353181.