SALEM, MA —
OSHA Inspection: JOHN SKOURAS & CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JOHN SKOURAS & CO., INC. in 2 D ASHLEY STREET, SALEM, MA 01970 (NAICS 238170). OSHA activity number 335400396.
Where did this inspection happen?
- Establishment
- JOHN SKOURAS & CO., INC.
- Site address
- 2 D ASHLEY STREET
- City
- SALEM
- State
- MA
- ZIP
- 01970
- Mailing
- 13 MASON STREET, PEABODY, MA 01960
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.300 B01
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: (a) Location - Mason Street, Peabody, MA: On or about 7/25/12, the employer failed to ensure employee were protected from struck by hazards when employees were using saws with missing guards.
Recent events (1)
- — Z (S) $2800
1926.403 B02
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) Location - Mason Street, Peabody, MA: On or about 7/25/12, employee were exposed to electrical shock and burns while using a relocatable power tap that was not designed for use on construction sites.
Recent events (1)
- — Z (S) $2000
1926.404 B01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. (a) Location - Mason Street, Peabody, MA: On or about 7/25/12, Employees were exposed to electrical shock and burns while using electrical receptacles that were not GFCI protected.
Recent events (1)
- — Z (S) $0
1926.453 B02 V
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: (a) Location - Mason Street, Peabody, MA: On or about 7/25/12, the employer failed to ensure employee were using fall protection while working in an aerial lift.
Recent events (1)
- — Z (S) $2800
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335400396.