OSHA Inspection: PAUL HOSTETTER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PAUL HOSTETTER in 210 SKYVIEW DRIVE, VANDALIA, OH 45377 (NAICS 238160). OSHA activity number 335424602.

Watch Paul Hostetter — free Get an email when a new federal OSHA severe-injury report for Paul Hostetter is published. One employer, no account, unsubscribe in one click.
Establishment
PAUL HOSTETTER
Site address
210 SKYVIEW DRIVE
City
VANDALIA
State
OH
ZIP
45377
Mailing
3407 WINTERWOOD DRIVE, DAYTON, OH 45424
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.404(b)(1)(i):     General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    On or about July 26, 2012, at 210 Skyview Drive, Vandalia, an employee was exposed to an electrical shock hazard while operating a circular saw without ground fault circuit interruper protection due the an the extension cord plugged directly into the house outside two receptacle 110 Volt AC electrical outlet.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13):     "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    On or about July 26, 2012, at  210 Skyview Drive, Vandalia, employees were exposed to a 8'  fall hazard while working on the roof of a 8/12 pitch roof on a single family home.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.1053(b)(1):     When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    On or about July 26, 2012, at 210 Skyview Drive, Vandalia, employees were exposed to a fall hazard due to a portable metal extension ladder used to gain access to the roof on a single family home extended only 30 inches above the upper landing service.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335424602.