NORCROSS, GA —
OSHA Inspection: JUAN MUNOZ DAVILA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JUAN MUNOZ DAVILA in LOT 21, WOOD FOREST DR., NORCROSS, GA 30092 (NAICS 238140). OSHA activity number 335507406.
Where did this inspection happen?
- Establishment
- JUAN MUNOZ DAVILA
- Site address
- LOT 21, WOOD FOREST DR.
- City
- NORCROSS
- State
- GA
- ZIP
- 30092
- Mailing
- 1101 EASTSIDE DR., LOT 427, MARIETTA, GA 30060
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.300 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: On or about July 24, 2012, employee was exposed to struck-by hazards when the mixer was missing the grate cover over the mixing mechanism.
Recent events (1)
- — Z (S) $1600
1926.451 B01
- Issued
- Penalty
- Initial $1360.00 · Current $1360.00
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no wider than one inch: On or about July 24, 2012, employees were exposed to fall hazards of approximately 13 feet when the scaffold was not fully planked.
Recent events (1)
- — Z (S) $1360
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. On or about July 24, 2012, employees were exposed to fall hazards of up to approximately 13-15 feet when there was no ladder to provide access to the second level.
Recent events (1)
- — Z (S) $1600
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about July 24, 2012, employees were exposed to fall hazards of approximately 13-14 feet when the scaffold had not been inspected by a competent person who could recognize and correct hazards such as, but not limited to, missing guardrails, working levels not fully planked, missing toe boards, and a missing ladder.
Recent events (1)
- — Z (S) $1600
1926.451 G01 VI
- Issued
- Penalty
- Initial $1360.00 · Current $1360.00
General-duty citation text
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity). On or about July 24, 2012, employees were exposed to fall hazards of approximately 13-15 feet when the scaffold did not have guardrails on the ends of the scaffold or on the ends of the outriggers.
Recent events (1)
- — Z (S) $1360
1926.451 H02 II
- Issued
- Penalty
- Initial $1360.00 · Current $1360.00
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: On or about July 24, 2012, employee working below the scaffold was exposed to struck-by hazards when the scaffold did not have toe boards on the scaffold to prevent materials from falling below.
Recent events (1)
- — Z (S) $1360
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) On or about July 24, 2012, employees were exposed to chemical hazards when the employer did not have a written hazard communication program. Employees were exposed to chemicals such as, but not limited to, mortar mix.
Recent events (1)
- — Z (O) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical which they used: (Construction Reference: 1926.59) On or about July 24, 2012, employees were exposed to chemical hazards when the employer did not have a safety data sheet for each chemical in use. Employees were exposed to chemicals such as, but not limited to, mortar mix.
Recent events (1)
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) On or about July 24, 2012, employees were exposed to chemical hazards when the employer did not provide employees information on the location of the program and MSDS. Employees were exposed to chemicals such as, but not limited to, mortar mix.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335507406.