Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PLUS K CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PLUS K CONSTRUCTION, INC. in 1230 3RD AVENUE, NEW YORK, NY 10021 (NAICS 238350). OSHA activity number 335562641.

Watch Plus K Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Plus K Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1230 3RD AVENUE
City
NEW YORK
State
NY
ZIP
10021
Mailing
162-19 DEPOT ROAD, FLUSHING, NY 11358
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
11
Ownership type
A

8 citations on file for this inspection.

1926.304 H

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.304(h): Circular cross cut table saw was not guarded by a hood which shall meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws.    Located at 1230 3rd Avenue, New York, NY    On or about 8/2/2012    a)  Employees were using a 10" Ridge Table Saw TS-UV to cut Coran and the saw was not equipped with a guard.
Recent events (1)
  • — Z (S) $2800

1926.403 B02

Serious Gravity 5 1 instance 11 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.      Located at 1230 3rd Avenue, New York, NY    On or about 8/2/2012    a)  Employees were using extension cords to energize power tools which was plugged into a duplex outlet/receptacle which was lying on the floor.  The 1900 Junction box was not mounted and installed as for its listing and labeling.
Recent events (1)
  • — Z (S) $2000

1926.403 I02 I

Serious Gravity 5 1 instance 11 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.403(i)(2)(i):  Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, or by any means:     Located at 1230 3rd Avenue, New York, NY    On or about 8/2/2012    a)  A 240 VAC Circuit Breaker Panel located in an active work area was not protected by a cover.  Energized parts not protected or guarded as employees worked in the room.
Recent events (1)
  • — Z (S) $2000

1926.404 F06

Serious Gravity 5 3 instances 11 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    Located at 1230 3rd Avenue, New York, NY    On or about 8/2/2012    a)  Duplex outlets/receptacles used to energize extension cords and power tools did not have a permanet and continuous path to ground.
Recent events (1)
  • — Z (S) $2000

1926.405 G02 III

Serious Gravity 5 1 instance 11 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iii):  Splices. Flexible cords were not used only in continuous lengths without splice or tap.     Located at 1230 3rd Avenue, New York, NY    On or about 8/2/2012    a)  Employees were using extension cords to energize power tools and the cord was cut and spliced.    b)  Employee using a Festol RO150 FEQ sander and the cord was spliced.
Recent events (1)
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.    Located at 1230 3rd Avenue, New York, NY    On or about 8/2/2012    a)  An employee was using a Festol RO150 FEQ sander and the cord was not provided with strain relief.
Recent events (1)
  • — Z (S) $0

1926.405 B02

Serious Gravity 5 3 instances 11 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:    Located at 1230 3rd Avenue, New York, NY    On or about 8/2/2012    a)  Energized electrical outlets missing covers.  Electrical outlets being used to energize extension cords, power tools and table saw.
Recent events (1)
  • — Z (S) $2000

1926.451 F14

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees:    Located at 1230 3rd Avenue, New York, NY    On or about 8/2/2012    a)  Employee painting a ceiling soffet while standing on an unstable work platform.  Employee standing on a plastic bucket located on top of a counter and the bucket was placed on a 2x4 piece of lumber and other wood scraps to increase the working level height.
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335562641.