Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTHERN PUMP & POUR, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTHERN PUMP & POUR, INC. in 5070 CARRELLTON LOT 13, APOPKA, FL 32704 (NAICS 238140). OSHA activity number 335633988.

Watch Southern Pump & Pour, INC. — free Get an email when a new federal OSHA severe-injury report for Southern Pump & Pour, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5070 CARRELLTON LOT 13
City
APOPKA
State
FL
ZIP
32704
Mailing
P.O. BOX 473, APOPKA, FL 32704
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.501(b)(13):  Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b).    Note:  If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502.         a. On or about July 30, 2012, employees performing residential construction were walking on the top of the block walls pumping concrete into the walls without the use of a fall protection system exposing them to a fall hazard of 10 feet to the concrete slab below.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1053 A08

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2040.00 · Current $1224.00 Reduced
29 CFR 1926.1053(a)(8):  A metal spreader or locking device was not provided on each stepladder to hold the front and back sections in an open position when the ladder was being used:        a. On or about July 30, 2012, the step ladder used by employees to gain access to the top of a 10-foot wall had a           damaged spreader bar causing it to be used in its collapsed position.
Recent events (2)
  • — I (S) $1224
  • — Z (S) $2040

1926.1053 B13

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1926.1053(b)(13): The top or top step of a stepladder shall not be used as a step.        a.  On or about July 30, 2012, two employees stood on the top of a 7 foot step ladder to climb to the top of a 10-           foot wall.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

View SOUTHERN PUMP & POUR, INC.'s full OSHA safety record →