BILLINGS, MT —
OSHA Inspection: YELLOWSTONE ICE & WATER INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of YELLOWSTONE ICE & WATER INC. in 1718 4TH AVENUE NORTH, BILLINGS, MT 59101 (NAICS 312113). OSHA activity number 335785788.
Where did this inspection happen?
- Establishment
- YELLOWSTONE ICE & WATER INC.
- Site address
- 1718 4TH AVENUE NORTH
- City
- BILLINGS
- State
- MT
- ZIP
- 59101
- Mailing
- 1718 4TH AVENUE NORTH, BILLINGS, MT 59101
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 312113
- Employees
- 11
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1480.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) Production Area: On or about August 15, 2012, and at times prior thereto, an employee was exposed to a fall hazard of approximately 13 feet while replacing diffusers in the ice maker without fall protection.
Recent events (2)
- — I (S) $1480
- — Z (S) $2000
1910.145 C02 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices: (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to the hazards associated with ammonia and were not provided with signs to adequately warn them of the potential hazards.
Recent events (2)
- — I (S) $500
- — Z (S) $2000
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to unexpected energization hazards while performing maintenance on equipment such as, but not limited to, the Turbo block press which contains electrical and hydraulic energy sources. The employer did not develop and implement specific procedures to de-energize these energy sources prior to maintenance. (b) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to unexpected energization hazards while performing maintenance on equipment such as, but not limited to, the Matthiesen 20lb bagger which contains electrical and pneumatic energy sources. The employer did not develop and implement specific procedures to de-energize these energy sources prior to maintenance.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to electrical and amputation hazards while conducting maintenance on equipment such as, but not limited to, the Matthiesen 20lb bagger and the Turbo block press. The employer did not provide adequate training to ensure employees understood the hazards of multiple energy sources when conducting maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.38 D
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.38(d): Employee alarm system. An employer must have and maintain an employee alarm system. The employee alarm system did not comply with the requirements in 1910.165: (a) Bin Freezer: On or about August 15, 2012, and at times prior thereto, employees were exposed to the hazards associated with ammonia and were not provided with an adequate alarm system to comply with the requirements set forth in 1910.165. The alarm could not be heard while employees were in the bin freezer.
Recent events (2)
- — I (S) $500
- — Z (S) $2800
1910.165 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.165(b)(2): The employee alarm could not be perceived above ambient noise or light levels by all employees in the affected portions of the workplace: (a) Bin Freezer: On or about August 15, 2012, and at times prior thereto, employees were exposed to the hazards associated with ammonia and were not provided with an adequate alarm system to be heard while in the bin freezer.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to amputation hazards while operating equipment such as, but not limited to, the Matthiesen 7lb bagging machine with unguarded ingoing nip points.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.219 C03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven (7) feet or less from floor or working platform was not enclosed with stationary casing(s): (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to the hazard of amputation and becoming caught in an unguarded vertical rotating shaft while operating equipment such as, but not limited to, the Ring Bag Closer.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to amputation hazards while operating equipment such as, but not limited to, the Ring Bag Closer with an unguarded chain and sprocket system.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.219 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to amputation hazards while operating equipment such as, but not limited to, the Ring Bag Closer with an unguarded gear system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 E01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to electrical shock hazards while operating the Turbo block press with an uncovered electrical outlet in a wet location.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Production Area: On or about August 15, 2012, and at times prior thereto, employees were exposed to electrical shock hazards while operating the Hamer bag tier in wet conditions with an attached power cord plugged into the block press in which the strain relief was damaged.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 312113)
HANOVER, PA—2026-05-12
THE HOME CITY ICE COMPANY
JOHNSON CITY, TN—2025-12-03
HARMAN BROTHERS' ICE, LLC
TORRANCE, CA—2025-11-10
SOUTHERN CALIFORNIA ICE COMPANY
UPPER CHICHESTER, PA—2025-09-26
ARCTIC GLACIER U.SA., INC.
CUPEY, PR—2025-07-18
CUPEY ALTO ICE PLANT, LLC
More inspections in MT
HELENA, MT—2026-06-17
VANILLA BEAN BAKERY, LLC
HELENA, MT—2026-06-15
SKYWEST AIRLINES, INC.
MISSOULA, MT—2026-06-02
HD ROOFING, LLC
MISSOULA, MT—2026-06-02
RHINO ROOFING LLC
MANHATTAN, MT—2026-06-02
MONTANA ROOFING & SIDING PROS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335785788.