Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: GUERRERO COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GUERRERO COMPANY in 770 GLENNBROOKE BLVD, PRATTVILLE, AL 36066 (NAICS 238140). OSHA activity number 335820197.

Watch Guerrero Company — free Get an email when a new federal OSHA severe-injury report for Guerrero Company is published. One employer, no account, unsubscribe in one click.
Establishment
GUERRERO COMPANY
Site address
770 GLENNBROOKE BLVD
City
PRATTVILLE
State
AL
ZIP
36066
Mailing
118 APOLLO DRIVE, PIKE ROAD, AL 36064
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)    a)  770 Glennbrooke Blvd, Prattville AL; On or about August 15, 2012 and at times prior thereto the employer exposed employees to a 13 foot 5 inch fall hazard in that employees were allowed to work from the top level of a two bucks high scaffold that was not fully planked.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.451 G01 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(vii):     Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a)  770 Glennbrooke Blvd, Prattville AL; On or about August 15, 2012 and at times prior thereto the employer exposed employees to a 13 foot 5 inch fall hazard in that employees were allowed to work from the top level of a two bucks high scaffold without fall protection such as but not limited to guardrail systems, personal fall arrest systems, or safety net systems.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1926.451(c)(2)(i):     Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement:    a)  770 Glennbrooke Blvd, Prattville AL; On or about August 15, 2012 and at times prior thereto the employer exposed employees to a 13 foot 5 inch fall hazard in that employees were allowed to work from the top level of a two bucks high scaffold that was erected on footings of wood and brick scraps set in dirt. The footing were not level, sound, or rigid.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.      a)  770 Glennbrooke Blvd, Prattville AL; On or about August 15, 2012 and at times prior thereto the employer exposed employees to a 13 foot 5 inch fall hazard in that employees were allowed to climb up the side of a two bucks high scaffold without the use of a ladder or other means of safe access.  Crossbraces were used as a means of access.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.403 I02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.403(i)(2)(i):     Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.    a)  770 Glennbrooke Blvd, Prattville AL; On or about August 15, 2012 the employer exposed employees to electrical hazards in that employees were allowed to walk and work around 110 volt AC bare conductors that were exposed without insulation or guarding.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.702 I01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.702(i)(1):     Masonry saws were not guarded with a semicircular enclosure over the blade:    a)  770 Glennbrooke Blvd, Prattville AL; On or about August 15, 2012 the employer exposed employees to struck by hazards in that employees were allowed to use a masonary saw that had the blade guard tied up into the retracted position.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335820197.