SMYRNA, GA —
OSHA Inspection: ONESIMO MEDINA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ONESIMO MEDINA in 2314 OAKTON PLACE, SMYRNA, GA 30080 (NAICS 423330). OSHA activity number 335877981.
Where did this inspection happen?
- Establishment
- ONESIMO MEDINA
- Site address
- 2314 OAKTON PLACE
- City
- SMYRNA
- State
- GA
- ZIP
- 30080
- Mailing
- 6160 PARKER ROAD, DORAVILLE, GA 30340
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423330
- Employees
- 1
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a. Worksite - The ground pin on the portable air compressor was missing exposing employees to shock hazards.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 B03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling. a. Worksite - The employee working on the scaffold on the edge of the building was exposed to falls because the scaffold work platform was greater than 14 inches from the surface being worked on.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 B05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end. a. Worksite - The platform was not installed so that the cantilevered portion of the platform was able to support the employee without failure at the portion of the platform which overhung the scaffold pick.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B10
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were intermixed such that the components fit together with force and the scaffold's structural integrity was not maintained by the user: a. Worksite - The scaffold was used with different manufacturers components in that one aluminum pick was supported by a second aluminum pick on the warner ladder rung and the pump jack scaffold which was of a different manufacturer thereby exposing employees to falls of 21 feet in the event of ladder, pick or scaffold failure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a. Worksite - The pump jack scaffold poles were not supported on base plates thereby exposing employees to falls of 21 feet in the event of a scaffold failure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a. Worksite - The footing on the pump jack scaffold were not level and sound thereby exposing employees to falls of 21 feet in the event of a scaffold collapse.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. Worksite - The employee using the scaffold were exposed to falls of 21 feet. These employees were not protected from falls by the use of a fall protection system
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) a. 2318 Oakton Place Smyrna Georgia - The employee who was engaged in residential construction was not protected from falls of 18 feet to the ground below when working from the roof.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder. a. Worksite - The ladder did not extend at least 3 feet above the level of the landing surface exposing employees to falls of 20-21 feet.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections in this industry (NAICS 423330)
SPOKANE VALLEY, WA—2026-07-15
WA317992075 - SRS DISTRIBUTION INC
KLAMATH FALLS, OR—2026-07-07
317744722 - NORTHWEST QUALITY ROOFING LLC
PORT ORCHARD, WA—2026-06-25
WA317991918 - CONVOY SUPPLY INC
ROSEVILLE, CA—2026-06-23
RWC BUILDING PRODUCTS - SACRAMENTO
PASADENA, TX—2026-06-22
IDEAL PRODUCTS OF AMERICA
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335877981.