Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TITAN COMPANIES INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TITAN COMPANIES INC. in 302 N. MORRISON ST., APPLETON, WI 54911 (NAICS 238160). OSHA activity number 335892618.

Watch Titan Companies INC. — free Get an email when a new federal OSHA severe-injury report for Titan Companies INC. is published. One employer, no account, unsubscribe in one click.
Site address
302 N. MORRISON ST.
City
APPLETON
State
WI
ZIP
54911
Mailing
P.O. BOX 7363, APPLETON, WI 54912
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.1101 K08 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1700.00

Hazardous substances 9020

29 CFR 1926.1101(k)(8)(i):     Labels were not affixed to all products containing asbestos and to all containers containing such products, including waste containers:    a) The waste dumpster or bags inside holding asbestos-containing roofing materials were not labeled with an asbestos warning.                       Abatement Certification and Abatement Documentation Required.
Recent events (1)
  • — Z (S) $1700

1926.1101 M01 I B

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $1020.00
29 CFR 1926.1101(m)(1)(i)(B):     For employees otherwise required by this standard to wear a negative pressure respirator, employers did not ensure employees are physically able to perform the work and use the equipment. This determination was not made under the supervision of a physician:    Employees removing asbestos-containing shingles at 302 N. Morrison St. in Appleton, Wisconsin, on 8/23/12, and utilizing MSA Model 3411 air purifying respirators were not provided with medical surveillance prior to wearing the respirators.     ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (1)
  • — Z (S) $1020

1926.1101 H02 I

Serious Gravity 1 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1101(h)(2)(i):     The employer did not implement a respiratory protection program in accordance with 1910.134 (b) through (d) (except (d)(1)(iii)), and (f) through (m), which covered each employee required by this section to use a respirator:    a) A written respirator program was not established (as required by 1910.134(c)) for employees utilizing MSA Model 3411 1/2 mask air purifying respirators to protect them against asbestos exposures, and while performing Class II asbestos removal.     b) Fit testing was not performed (as required by 1910.134(f)) for employees utilizing MSA Model 3411 1/2 mask air purifying respirators to protect them against asbestos exposures, and while performing Class II asbestos removal.    c) Procedures for regularly evaluating the effectiveness of the respirator program were not established (as required by 1910.134(l)) for employees utilizing MSA Model 3411 1/2 mask air purifying respirators to protect them against asbestos exposures, and while performing Class II asbestos removal.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (1)
  • — Z (S) $0

View TITAN COMPANIES INC.'s full OSHA safety record →