Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JWF CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JWF CONSTRUCTION in 738 SEA STREET, QUINCY, MA 02169 (NAICS 236115). OSHA activity number 335892998.

Watch JWF Construction — free Get an email when a new federal OSHA severe-injury report for JWF Construction is published. One employer, no account, unsubscribe in one click.
Establishment
JWF CONSTRUCTION
Site address
738 SEA STREET
City
QUINCY
State
MA
ZIP
02169
Mailing
86 ROCK ISLAND ROAD, QUINCY, MA 02169
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.102(a)(1):     Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.      Location:  Jobsite at 738 Sea Street, Quincy, MA    Employees were exposed to struck-by hazards from flying debris and ricochets, while using pneumatic nail guns to fasten shingles to a roof, and were not protected by safety glasses.
Recent events (1)
  • — Z (S) $2000

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13):     Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by  guardrail systems, safety net systems, or personal fall arrest systems, nor were employee(s) provided with alternative fall protection measures under another provision of paragraph (b)      Location:  Rooftop, 738 Sea Street, Quincy, MA    Employees were exposed to 25-30 foot fall hazards while installing shingles on a 6/12 pitch roof, where fall protection had not been used or provided.
Recent events (1)
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1):     Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:      Location:  Jobsite at 738 Sea Street, Quincy, MA    Employees were exposed to a fall hazard of 24 feet while working from a carpenter wall bracket scaffold that had no guardrail systems or end rail systems, nor were personal fall arrest systems used or provided.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335892998.