Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JEWETT BROTHERS HOME IMPROVEMENT, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JEWETT BROTHERS HOME IMPROVEMENT, INC. in ST. ANTHONY'S CHURCH, 422 TILDEN AVENUE, UTICA, NY 13501 (NAICS 238160). OSHA activity number 336011184.

Watch Jewett Brothers Home Improvement, INC. — free Get an email when a new federal OSHA severe-injury report for Jewett Brothers Home Improvement, INC. is published. One employer, no account, unsubscribe in one click.
Site address
ST. ANTHONY'S CHURCH, 422 TILDEN AVENUE
City
UTICA
State
NY
ZIP
13501
Mailing
9917 MORGAN ROAD, MARCY, NY 13403
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

4 citations on file for this inspection.

1926.252 A

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1926.252(a):  An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):    a) South side of roof, on or about 8-29-12:  Employees were discarding roofing debris over the edge of a roof , dropping the debris to the ground 25feet below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.404 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1926.404(b)(1)(ii):  On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:    a) South side of the building, on or about 8-29-12:  One employee was operating a hand held circular saw, powered through a duplex receptacle and extension cord that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.501 B11

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(11):  Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    a) South side of roof, on or about 8-29-12:  Five employees were performing roofing work on a 7:12 pitch roof and were not protected from falls, exposing the employees to a fall hazard of 25 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a) South side of roof, on or about 8-29-12:  Five employees were using a portable ladder for access and egress to the roof that was not extended 3 feet above the landing surface, exposing the employee to a fall hazard of 25 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000