Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BETHESDA CONTRACTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BETHESDA CONTRACTING in 3818 1/2 HARRISON ST., NW, WASHINGTON, DC 20015 (NAICS 236118). OSHA activity number 336104583.

Watch Bethesda Contracting — free Get an email when a new federal OSHA severe-injury report for Bethesda Contracting is published. One employer, no account, unsubscribe in one click.
Site address
3818 1/2 HARRISON ST., NW
City
WASHINGTON
State
DC
ZIP
20015
Mailing
6812 FLORIDA ST., CHEVY CHASE, MD 20815
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1926.501(b)(13):  Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b):    a)  Second Floor Ledge - A laborer installing Tyvek wrap around a newly installed window was not provided with fall protection and exposed to a 14 ft. fall to the earth below.
Recent events (1)
  • — Z (S) $2400

1926.404 B01 III

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(iii):  Where ground-fault circuit interrupters were not utilized, employer did not establish and implement an assured equipment grounding conductor program on the construction site covering all cord sets, receptacles which are not part of the building or structures, and equipment connected by cord and plug which are available for use or used by employees:     a) Front Yard - A wet saw used to cut ceramic tile and which was provided temporary power was not provided with ground fault circuit interrupter circuitry or and assured equipment grounding conductor program.    b)  Back Yard - A Makita miter saw used for cutting wood and which was provided temporary power was not provided with ground fault circuit interrupter circuitry or and assured equipment grounding conductor program.
Recent events (1)
  • — Z (O) $0

MACY'S

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336104583.