WASHINGTON, DC —
OSHA Inspection: BETHESDA CONTRACTING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BETHESDA CONTRACTING in 3818 1/2 HARRISON ST., NW, WASHINGTON, DC 20015 (NAICS 236118). OSHA activity number 336104583.
Where did this inspection happen?
- Establishment
- BETHESDA CONTRACTING
- Site address
- 3818 1/2 HARRISON ST., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20015
- Mailing
- 6812 FLORIDA ST., CHEVY CHASE, MD 20815
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2400.00 · Current $2400.00
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b): a) Second Floor Ledge - A laborer installing Tyvek wrap around a newly installed window was not provided with fall protection and exposed to a 14 ft. fall to the earth below.
Recent events (1)
- — Z (S) $2400
1926.404 B01 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(iii): Where ground-fault circuit interrupters were not utilized, employer did not establish and implement an assured equipment grounding conductor program on the construction site covering all cord sets, receptacles which are not part of the building or structures, and equipment connected by cord and plug which are available for use or used by employees: a) Front Yard - A wet saw used to cut ceramic tile and which was provided temporary power was not provided with ground fault circuit interrupter circuitry or and assured equipment grounding conductor program. b) Back Yard - A Makita miter saw used for cutting wood and which was provided temporary power was not provided with ground fault circuit interrupter circuitry or and assured equipment grounding conductor program.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 236118)
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
SYRACUSE, NY—2026-07-14
EMPIRE BUILDERS OF CNY, INC.
RENTON, WA—2026-07-14
WA317992055 - JCC INVESTMENT GROUP LLC
RIVERTON, NJ—2026-07-14
JBF CONSTRUCTION LLC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336104583.