Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRIPLE K ROUSTABOUTS INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of TRIPLE K ROUSTABOUTS INC. in DAVIS 1A, 1B, 1C 9H, FORT LUPTON, CO 80621 (NAICS 221210). OSHA activity number 336143185.

Watch Triple K Roustabouts INC. — free Get an email when a new federal OSHA severe-injury report for Triple K Roustabouts INC. is published. One employer, no account, unsubscribe in one click.
Site address
DAVIS 1A, 1B, 1C 9H
City
FORT LUPTON
State
CO
ZIP
80621
Mailing
21791 WCR 53, KERSEY, CO 80644
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221210
Employees
11
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
Section (5)(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to struck-by hazards due to the inadvertent release of pressurized natural gas:    (a)Triple K Roustabouts at Davis 1a, 1b, 1c 9H, Fort Lupton, CO 80621:  On August 15, 2012 the employer did not ensure that employees engaged in connecting a flowline extension to the well head were protected from struck-by hazards associated with pressurized natural gas.  The employer did not have sufficient procedures and controls implemented to effectively ensure the pipeline was de-energized (flowline and riser blown down) before work began that led to a catastrophic release of natural gas.  This condition exposed the employees to a struck-by hazard.    Abatement Note:  Among other methods, one feasible and acceptable method to correct this hazard is to develop and implement specific procedural elements to control hazardous energy in accordance with the American Petroleum Institute (API) recommended practice 74 section 6.3 Lockout/Tagout which states: A lockout/tagout program shall be established to control hazardous energy as follows: (b) Personnel should be trained and disciplined in the  use of this system to prevent unexpected operations of any equipment that stores any type of energy that might inflict injury to personnel.
Recent events (1)
  • — Z (S) $2800

View TRIPLE K ROUSTABOUTS INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336143185.