JACKSONVILLE, FL —
OSHA Inspection: OLDCASTLE RETAIL INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of OLDCASTLE RETAIL INC. in 6659 HIGHWAY AVE., JACKSONVILLE, FL 32254 (NAICS 327331). OSHA activity number 336163183.
Where did this inspection happen?
- Establishment
- OLDCASTLE RETAIL INC.
- Site address
- 6659 HIGHWAY AVE.
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32254
- Mailing
- 6659 HIGHWAY AVE., JACKSONVILLE, FL 32254
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327331
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Penalty
- Initial $2890.00 · Current $2300.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion, laceration and puncture hazards: a. On or about September 5, 2012, the employer was using polyvinyl chloride (PVC) pipe to transport air with a pressure of 110 pounds per square inch (psi) to operate equipment in the maintenance shop. The PVC piping was not approved for use with compressed air, and could fail or rupture, exposing employees to laceration and punctured hazards.
Recent events (2)
- — I (S) $2300
- — Z (S) $2890
1910.253 B02 IV
- Issued
- Penalty
- Initial $2890.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a. On or about September 5, 2012, employees working outside and around the storage room on the north end of the production building, were exposed to a fire and explosion hazard because an oxygen cylinder was stored on a welding cart. The oxygen cylinder's regulator had been removed and the oxygen cylinder was uncapped.
Recent events (2)
- — I (O) $1000
- — Z (S) $2890
1910.253 B04 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a. On or about September 5, 2012, employees working outside and around the storage room on the north end of the production building, were exposed to a fire and explosion hazard because an oxygen and an acetylene cylinder were stored side-by-side on a welding cart. The oxygen cylinder's regulator had been removed and was uncapped.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections in this industry (NAICS 327331)
SESSER, IL—2026-07-01
SESSER CONCRETE PRODUCTS COMPANY
CLARKSVILLE, TN—2026-06-30
OLDCASTLE APG SOUTH, INC.
EUGENE, OR—2026-05-28
317744337 - WILLAMETTE GRAYSTONE LLC
CHRISTIANSBURG, VA—2026-05-27
CHANEY MATERIALS, LLC
HANOVER, PA—2026-05-26
HANOVER PREST PAVING INC.
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336163183.