Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JAMES DUNLAP CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAMES DUNLAP CONSTRUCTION, LLC in 100 COUNTY LINE ROAD, NORTH LIMA, OH 44452 (NAICS 236115). OSHA activity number 336181987.

Watch James Dunlap Construction, LLC — free Get an email when a new federal OSHA severe-injury report for James Dunlap Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
100 COUNTY LINE ROAD
City
NORTH LIMA
State
OH
ZIP
44452
Mailing
12999 SOUTH AVENUE EXTENSION, NORTH LIMA, OH 44452
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 E05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1926.451(e)(5)(i):  Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part -- Fall Protection:    Employees accessed a scaffold platform via an inclined, unguarded ramp and were exposed to a fall of about 12 feet
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $510.00 Reduced
29 CFR 1926.1053(b)(1):  When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:    The ladder used to access a roof extended about 1.5 feet above the roof's surface and was not secured at the top.
Recent events (2)
  • — I (S) $510
  • — Z (S) $1020

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4):  Ladders shall be used only for the purpose for which they were designed:    A 12 foot step ladder used by employees to gain access to a roof was used as if it were an extension ladder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336181987.