Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DICKSON PROCESS SYSTEMS LTD.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DICKSON PROCESS SYSTEMS LTD. in 3912 CR 1290 SOUTH, MIDLAND, TX 79711 (NAICS 333132). OSHA activity number 336185038.

Watch Dickson Process Systems LTD. — free Get an email when a new federal OSHA severe-injury report for Dickson Process Systems LTD. is published. One employer, no account, unsubscribe in one click.
Site address
3912 CR 1290 SOUTH
City
MIDLAND
State
TX
ZIP
79711
Mailing
10925 CR 125, MIDLAND, TX 79705
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333132
Employees
42
Ownership type
A

7 citations on file for this inspection.

1910.146 C04

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3430.00 Reduced
29 CFR 1910.146(c)(4):     When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:    On or about September 5, 2012 in the vessel shop employees were exposed to an oxygen defecient atmosphere when the employer failed to implement a written permit space entry program for employees entering pressure vessels.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1910.212 A01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about September 5, 2012 in the vessel shop employees were exposed to amputation hazards when the employer failed to provide point of operation guarding on an Ironworker punch press.
Recent events (2)
  • — I (O) $2100
  • — Z (S) $3500

1910.243 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2100.00 Reduced
29 CFR 1910.243(c)(3):     Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:    On or about September 5, 2012 in the vessel shop employees were exposed to a severing hazards when a hand held grinder was used without a guard covering 180 degrees of the wheel.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1910.253 B02 IV

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1000.00 Reduced
29 CFR 1910.253(b)(2)(iv):     Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:    On or about September 5, 2012 in the compressed gas cylinder storage area, employees were exposed to struck-by hazards when valve protection caps were not installed on compressed gas cylinders.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $2800

1910.254 D08

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.254(d)(8):     Welding cables with splices within 10 feet (3 m) of the holder were used:    On or about September 5, 2012 in the vessel shop employees were exposed to arch flash when welding leads were repaired within 10 ft. of the holder.
Recent events (2)
  • — I (O) $1400
  • — Z (S) $2800

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $2100.00
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On or about September 5, 2012 in the west yard area shed employees were exposed to electrical shock hazards when flexible cable was used to wire a permanet light fixture.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2100

1910.303 F02

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    On or about September 5, 2012 in the vessel shop on the west wall employees were exposed to the hazard of not being able to shut down equipment in an emergency when the circuit breaker panel switches were not marked indicating function.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336185038.