Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: CHOICE CONCRETE COMPANY, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHOICE CONCRETE COMPANY, LLC in 117 PAT JOINER BLVD., BYRON, GA 31008 (NAICS 327320). OSHA activity number 336254198.

Watch Choice Concrete Company, LLC — free Get an email when a new federal OSHA severe-injury report for Choice Concrete Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
117 PAT JOINER BLVD.
City
BYRON
State
GA
ZIP
31008
Mailing
P.O. BOX 1359, BYRON, GA 31008
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
14
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l)    On or about 09/11/12 at Byron, GA: Employees were exposed to struck-by hazards when operating forklifts at the concrete mixing plant.  The employer failed to implement a forklift driver training and evaluation program.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.178 Q01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1020.00 Reduced
29 CFR 1910.178(q)(1):     Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1910.212 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Penalty
Initial $1700.00 · Current $1020.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about 09/11/12 at Byron, GA:  Employees were exposed caught between hazards while performing work adjacent to unguarded conveyor belt ends at a concrete mix plant.  The employer failed to properly guard all ingoing nip points at the following locations:  a. Convyor System - Gravel:  The employer failed to properly guard the lower end of a conveyor system, which fed gravel into the hopper/bin at the mixing plant.  b. Conveyor System - Load Belt: The employer failed to properly guard the lower end of the load belt. Several holes were cut into the guard in order that maintenance could lubricate the conveyor system.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1910.253 B02 II

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    On or about 09/11/12 at Byron, GA: The unsecured compressed oxygen cylinder was located at the entrance of the breakroom.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.303 G02 I

Other-than-serious 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about 09/11/12 at Byron, GA: Employees were exposed to electrical hazards while working at the cement mixing plant.  The employer failed to provide a cover on a electrical panel, which was used in the chemical mixing process.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336254198.