2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: EXCEL ROOFING CONTRACTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EXCEL ROOFING CONTRACTORS, INC. in 1914 SAN MARIE AVENUE S., JACKSONVILLE, FL 32217 (NAICS 238160). OSHA activity number 336271986.

Watch Excel Roofing Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Excel Roofing Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1914 SAN MARIE AVENUE S.
City
JACKSONVILLE
State
FL
ZIP
32217
Mailing
5722 DUNN AVE., JACKSONVILLE, FL 32218
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a. On or about September 7, 2012, each employee engaged in installing roofing shingles on a 4:12 pitch roof were not protected from falling 11 feet to the ground by the use of a guardrail system, safety net system, personal fall arrrest system or any other type fall protection method.     Abatement Certification and Documentation are not required
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder:    a. On or about September 7, 2012, the ladder placed in front of the doorway to the home was not extended 3 feet past the landing and not secured to prevent accidential movement.    Abatement Certification and Documentation are not required
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View EXCEL ROOFING CONTRACTORS, INC.'s full OSHA safety record →