Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRAFCON INDUSTRIES, INCORPORATED

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of TRAFCON INDUSTRIES, INCORPORATED in 81 TEXACO ROAD, MECHANICSBURG, PA 17050 (NAICS 339950). OSHA activity number 336323191.

Watch Trafcon Industries, Incorporated — free Get an email when a new federal OSHA severe-injury report for Trafcon Industries, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
81 TEXACO ROAD
City
MECHANICSBURG
State
PA
ZIP
17050
Mailing
81 TEXACO ROAD, MECHANICSBURG, PA 17050
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
20
Ownership type
A

13 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced

Hazardous substances E200

29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity was maintained:    (a) Powder Coating Spray Booth - There were no guages in the booth to monitor the air velocity, on or about September 13, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.107 B05 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E200

29 CFR 1910.107(b)(5)(iv): The space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    (a) Powder Coating Spray Booth - The spray booth was not equipped with automatic sprinklers both upstream and downstream of the filters, on or about September 13, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G07

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.107(g)(7):  "No smoking" signs in large letters on contrasting color background were not conspicuously posted at all spraying areas and paint storage rooms:    (a) Spay Painting Building - "No Smoking" signs were not posted where electrostatic spraying and powder coating operations were conducted, on or about September 13, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.145 C03

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.145(c)(3): Safety instruction signs were not used where there was a need for general instructions and suggestions relative to safety measures:    (a) Outside Cylinder Storage Area - A "No Smoking" was not posted where the oxygen and fuel-gas cyinders were stored, on or about September 13, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 I04

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1120.00 Reduced

Hazardous substances E200

29 CFR 1910.107(i)(4): Transformers, powerpacks, control apparatus, and all other electrical portions of the equipment, with the exception of the handgun itself and its connections to the power supply were not located outside of the spraying area and did not otherwise conform to the requirements of paragraph (c) of this section:    (a) Powder Coating Spray Booth - The control apparatus was located inside of the booth, on or about September 13, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.107 I05

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E200

29 CFR 1910.107(i)(5): The handle of the spraying gun was not electrically connected to ground by a metallic connection and was not so constructed that the operator in normal operating position is in intimate electrical contact with the grounded handle:    (a) Powder Coating Spray Booth - The operator wore gloves and was not in intimate electrical contact with the grounded handle, on or about September 13, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 I08

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E200

29 CFR 1910.107(i)(8): The electrical equipment was not interlocked with the ventilation of the spraying area that the equipment could not be operated unless the ventilation fans are in operation:    (a) Powder Coating Spray Booth - The electrical equipment was not interlocked with the ventilation so that the spraying equipment could not be operated unless the ventilation was in operation, on or about September 13, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 L01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E200

29 CFR 1910.107(l)(1):  Electrical equipment and other sources of ignition did not conform to the requirements of paragraphs (c)(1)(i)-(iv), (8) and (9)(i) of this section and subpart S of this part:    (a) Powder Coating Spray Booth - There was a receptacle, an electrical switch, and the control apparatus for the Wagner spraying operation located within the spray booth, on or about September 13, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    (a) Outside Cylinder Storage Area - Oxygen cylinders were stored within 8' of propane and/or acetylene cylinders , on or about September 13, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E200

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) Painting Operation - The employer did not establish and implement a written respiratory protection program that included a respirator medical evaluation, fit-testing and training, on or about September 13, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 G01 I A

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E200

29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    (a)  Painting Operation - Tight-fitting respirators were worn by an employee who had facial hair that came between the sealing surface of the facepiece and the face, on or about September 13, 2012.    No abatement certification or documentation required
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 H04

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E200

29 CFR 1910.134(h)(4): Respirators that failed an inspection or were otherwise found to be defective were not removed from service and discarded or repaired:    (a)  Painting Operation - The head straps on the 3M fullface and halfmask respirators were in poor condition, on or about September 13, 2012.    No abatement certification or documentation required
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l)    (a) Trafcon Industries, Incorporated - The employer did not certify that the powered industrial truck operators had been trained and evaluated, on or about September 13, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View TRAFCON INDUSTRIES, INCORPORATED's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336323191.