Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JOSE ORELLANA ELECTRICAL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE ORELLANA ELECTRICAL in 909 MISTY OAK TRL, BURLESON, TX 76097 (NAICS 238210). OSHA activity number 336391602.

Watch Jose Orellana Electrical — free Get an email when a new federal OSHA severe-injury report for Jose Orellana Electrical is published. One employer, no account, unsubscribe in one click.
Site address
909 MISTY OAK TRL
City
BURLESON
State
TX
ZIP
76097
Mailing
7504 MARSHLAND LANE, ARLINGTON, TX 76001
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
24
Ownership type
A

1 citation on file for this inspection.

1926.404 F06

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.      On or about August 2, 2012, inside a residential building, extension cords were utilized to energize skill saws.  The ground pins were missing from two extension cords exposing employees to hazards of electrical shock.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336391602.