WASHINGTON, DC —
OSHA Inspection: TRADITIONAL MASONRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRADITIONAL MASONRY in 649 FLORIDA AVENUE, NW, WASHINGTON, DC 20001 (NAICS 238140). OSHA activity number 336609383.
Where did this inspection happen?
- Establishment
- TRADITIONAL MASONRY
- Site address
- 649 FLORIDA AVENUE, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20001
- Mailing
- 5013 WINDWOOD LN., RICHMOND, VA 23237
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.1052 C01 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with at least one handrail: (a) Rear Stairway - Workers were observed, using a metal stairway with 7 risers on its lower portion and 11 risers on it upper portion, to access their work area and there was no handrail, on or about September 21, 2012. ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $2800
1926.1052 C01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with one stairrail system along each unprotected side or edge: (a) Rear Stairway - Workers were observed, using a metal stairway that had 7 risers on lower level and 11 risers on the upper level to access their work area and it was missing a stairrail system, on or about September 21, 2012. ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $0
Citation 01001C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part: (a) Rear Stairway - Workers were observed, using a stairway to access their work area, that had a landing missing a guardrail system and they were exposed to a 10 feet 1 inch fall hazard, on or about September 21, 2012. ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $0
More inspections at TRADITIONAL MASONRY
WASHINGTON, DC—2015-07-08 00:00:00
TRADITIONAL MASONRY
WASHINGTON, DC—2013-12-04 00:00:00
TRADITIONAL MASONRY
WASHINGTON, DC—2013-05-08 00:00:00
TRADITIONAL MASONRY
View TRADITIONAL MASONRY's full OSHA safety record →
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336609383.