CINCINNATI, OH —
OSHA Inspection: OHM, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OHM, LLC in 5410 RIDGE AVE., CINCINNATI, OH 45213 (NAICS 238170). OSHA activity number 336692603.
Where did this inspection happen?
- Establishment
- OHM, LLC
- Site address
- 5410 RIDGE AVE.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45213
- Mailing
- 5410 RIDGE AVE., CINCINNATI, OH 45213
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. a) At the motel entranceway under construction, the employer had no safety and health program implimented for employees involved with construction activity.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. a) At the entranceway to the motel under construction, laborors had not received any training in the hazards associated with electrical, scaffolding safety and proper personal protective equipment to be worn.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. a) Under the entranceway to the motel, laboror(s) were using a DeWalt chop saw to cut metal studs with no eye protection being worn.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.404 B01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) At the entranceway to the existing motel , laboror(s) were using (2) extension cords for powering portable tools with no GFCI or AEGCP in use.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a) At the entranceway to the motel under construction, laboror(s) were exposed to an electrical shock hazard due to the use of (2) extension cords that were ungrounded.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports: a) At the entranceway to the motel, laboror(s) were exposed to fall hazards of 11 feet, 6 inches due to the tubular welded scaffold being worked from not being planked solid.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. a) At the entranceway to the motel, laboror(s) were exposed to a 11 feet, 6 inch fall hazard from the tubular welded frame scaffold being worked from due to no means of fall protection in use.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in OH
WELLINGTON, OH—2026-07-16