Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: T.F.I. CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of T.F.I. CONSTRUCTION LLC in 14 POST ROAD WEST, WESTPORT, CT 06880 (NAICS 238350). OSHA activity number 336849997.

Watch T.F.I. Construction LLC — free Get an email when a new federal OSHA severe-injury report for T.F.I. Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
14 POST ROAD WEST
City
WESTPORT
State
CT
ZIP
06880
Mailing
38 PINE TREE LANE, FAIRFIELD, CT 06825
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 E08

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1500.00 Reduced
29 CFR 1926.451(e)(8): Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally and not more than 24 inches (61 cm) vertically from the other surface.    WORKSITE: The employees, having direct access to the platform of the Alum-a-Pole pump jack scaffold from the extension ladder where the horizontal space between them was approximately 15 inches apart.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    WORKSITE: The employees, installing a window from the Alum-a-Pole pump jack scaffold were not protected from falling 17 feet to the ground by the use of appropriate fall arrest systems
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.    WORKSITE: The vertical poles of the Alum-a-Pole pump jack scaffold were not braced at the bottom of the poles.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1100.00 Reduced
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:    WORKSITE: The employees, working from the Alum-a-Pole pump jack scaffold, were not trained to recognize the hazards associated with the type of scaffold being used or the procedures necessary to eliminate or minimize those hazards.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336849997.