OSHA Inspection: PAULSON PRESS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PAULSON PRESS, INC. in 904 CAMBRIDGE DRIVE, ELK GROVE VILLAGE, IL 60007 (NAICS 323119). OSHA activity number 336874409.

Watch Paulson Press, INC. — free Get an email when a new federal OSHA severe-injury report for Paulson Press, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PAULSON PRESS, INC.
Site address
904 CAMBRIDGE DRIVE
City
ELK GROVE VILLAGE
State
IL
ZIP
60007
Mailing
904 CAMBRIDGE DRIVE, ELK GROVE VILLAGE, IL 60007
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323119
Employees
24
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:      (a) Facility Wide - An energy control procedure consisting of employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative was not established for machines or equipment including but not limited to the Polar Cutters.       In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    (a) Facility Wide - The employer did not ensure that each powered industrial truck operator operating the Toyota sit down fork truck and the Crown fork truck is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training, certification, and evaluations.         In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Printing Press Area (Heidelberg Speedmaster Press immediately adjacent to the entrance) - A four recepticle electrical outlet box located on the ground supplying power to a phone charger, extension cord, and a densitometer was not firmly secured to the surface on which it was mounted and was not used or installed in accordance with instructions included in the listing or labeling.     In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.303 G01 II

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    (a) Cutter Area - The required working space about the electrical switches supplying power to the cutters was used for storage of a table and a filing cabinet.     (b) Printing Area (along the wall that is facing the Heidelberg Speedmaster printing press which is immediate to the entrance of the printing room) - The required working space about an electrical panel was used for storage of trash and/or recycleables.        In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.305 B02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    (a) Printing Room (behind the Heidelberg Speedmaster Printing Press facing the entrace to the printing room) - An electrical panel did not have its cover on and was not guarded against accidental contact.       In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0