SUPERIOR, WI —
OSHA Inspection: EXODUS MACHINES, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EXODUS MACHINES, LLC. in ONE EXODUS DRIVE, SUPERIOR, WI 54880 (NAICS 333923). OSHA activity number 336917992.
Where did this inspection happen?
- Establishment
- EXODUS MACHINES, LLC.
- Site address
- ONE EXODUS DRIVE
- City
- SUPERIOR
- State
- WI
- ZIP
- 54880
- Mailing
- ONE EXODUS DRIVE, SUPERIOR, WI 54880
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333923
- Employees
- 65
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1666.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) Throughout the facility; Machine specific lockout procedures did not identify each energy source and how to isolate them for equipment such as, but not limited to; burn table, boring mill, lathe, vertical milling machine, and horizontal band saw.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.147 C04 II C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: (a) Fabricating area; Steps for transferring lockout devices were not developed. (b) Fabricating area; Lockout device removal procedures did not identify steps for contacting the original installer.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Fabricating area; Energy isolation procedures were not evaluated within the last year.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1666.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Fabricating area; Energy isolation devices were not used during cleaning and setup operations on the Messer brand plasma burn table.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1666.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Fabricating area, Bridgeport mill; Guarding was not provided for the spindle and chuck. (b) Fabricating area, Bridgeport mill; Guarding was not provided for flying metal chips.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Fabricating area; Point of operation guarding was not provided for the unused portion of blade on a horizontal band saw.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B02 II
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1666.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: (a) Fabricating area, North exit; Compressed gas cylinders were not stored in a protected location.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
More inspections in this industry (NAICS 333923)
NORTH FT MYERS, FL—2026-06-30
GOLDEN MANUFACTURING, INC.
MARATHON, WI—2026-06-09
DAHL'S CRANE SERVICE LLC
NORTH BAY VILLAGE, FL—2026-06-01
HI-RISE CRANE, INC.
RICHARDSVILLE, KY—2026-05-28
69155 - WESTERN CRANE SERVICE INC
MC CONNELLSBURG, PA—2026-05-22
JLG INDUSTRIES, INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source