WATSEKA, IL —
OSHA Inspection: PRIDE METALS, L.L.C.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRIDE METALS, L.L.C. in 475 NORTH VETERANS PARKWAY, WATSEKA, IL 60970 (NAICS 337215). OSHA activity number 336967583.
Where did this inspection happen?
- Establishment
- PRIDE METALS, L.L.C.
- Site address
- 475 NORTH VETERANS PARKWAY
- City
- WATSEKA
- State
- IL
- ZIP
- 60970
- Mailing
- 475 NORTH VETERANS PARKWAY, WATSEKA, IL 60970
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337215
- Employees
- 131
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.217 C03 VIII A
- Issued
- Abate by
- Penalty
- Initial $5670.00 · Current $3920.00 Reduced
General-duty citation text
29 CFR 1910.217(c)(3)(viii)(a): Each operator of a mechanical power press was not provided with separate two hand trip devices: Employees were exposed to amputation hazards when operating press number 04 because there were two operators and only one set of two hand controls.
Recent events (2)
- — I (S) $3920
- — Z (S) $5670
1910.217 F02
- Issued
- Abate by
- Penalty
- Initial $4050.00 · Current $2790.00 Reduced
General-duty citation text
29 CFR 1910.217(f)(2): Supervision to ensure that correct operating procedures were being followed on mechanical power presses was inadequate: Employees were exposed to amputation hazards when operating press number FB-04 and LSL0015 because selector keys were left in the machines and were not under supervisory control.
Recent events (2)
- — I (S) $2790
- — Z (S) $4050
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $3240.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space about electric equipment rated 600 volts, nominal, or less was used for storage: Employees were exposed to electrical hazards because the facility main disconnect was blocked by chemical barrels. The employer did not ensure that the working space about electrical equipment was free of material and not used for storage.
Recent events (2)
- — I (O) $0
- — Z (S) $3240
1910.217 H09 IV
- Issued
- Abate by
- Penalty
- Initial $4050.00 · Current $2790.00 Reduced
General-duty citation text
29 CFR 1910.217(h)(9)(iv): Light curtains used for PSDI operation shall have minimum object sensitivity not to exceed one and one-fourth inches (31.75 mm). Where light curtain object sensitivity is user-adjustable, either discretely or continuously, design features shall limit the minimum object sensitivity adjustment not to exceed one and one-fourth inches (31.75 mm). Blanking of the sensing field is not permitted. Employees were exposed to amputation hazards when operating press number LSL0050 because a portion of the light curtain on the press was blanked out.
Recent events (2)
- — I (S) $2790
- — Z (S) $4050
1910.217 H10 II D
- Issued
- Abate by
- Penalty
- Initial $4050.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.217(h)(10)(ii)(D): A check shall be made to assure that the barriers and/or supplemental presence sensing devices required by paragraph (h)(9)(ix) of this section are operating properly. Employees were exposed to amputation hazards when operating press number LSL0050 because a portion of the light curtain on the press was blanked out and a preoperational inspection of the light curtain was not performed.
Recent events (2)
- — I (S) $0
- — Z (S) $4050
More inspections at PRIDE METALS, L.L.C.
WATSEKA, IL—2008-10-15 00:00:00
PRIDE METALS, L.L.C.
WATSEKA, IL—2007-09-18 00:00:00
PRIDE METALS, L.L.C.
WATSEKA, IL—2006-08-22 00:00:00
PRIDE METALS, L.L.C.
View PRIDE METALS, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 337215)
KALAMAZOO, MI—2026-07-13
BORROUGHS LLC
PLACENTIA, CA—2026-07-08
ALAN LEWIS INC.
MUSKEGON, MI—2026-06-26
DYNAMIC WOOD SOLUTIONS
MUSKEGON, MI—2026-06-26
DYNAMIC WOOD SOLUTIONS
HICKORY, NC—2026-06-18
161399 - ZAGAROLI AND COMPANY
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336967583.