Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HSI MECHANICAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HSI MECHANICAL, INC. in 227 PUUHALE ROAD, HONOLULU, HI 96819 (NAICS 332322). OSHA activity number 336967799.

Watch HSI Mechanical, INC. — free Get an email when a new federal OSHA severe-injury report for HSI Mechanical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
227 PUUHALE ROAD
City
HONOLULU
State
HI
ZIP
96819
Mailing
227 PUUHALE ROAD, HONOLULU, HI 96819
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
47
Ownership type
A

8 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 15 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Shop - In the following instances machine guarding was not provided:    a)     The Delta Drill Press was not equipped with a chuck guard to protect the operator from the rotating part.   b)     The Peck, Stout, Wilcox Co. electric roller's foot pedal was not guarded against accidental contact nor was an      emergency stop wire located along the length of the machine to protect the operator from the ingoing nip point.  c)      The Pexto rollers were not equipped with an emergency stop cord.  d)     The Chicago press brake's foot petal was not guarded against accidental contact to protect the operator from the  point of operation.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.212 A03 II

Serious Gravity 10 4 instances 15 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2940.00 Reduced
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    Shop - In the following instances the point of operation was not guarded:    a)    The Cincinnati 5 series press brake did not have the die area quarded.  b)    The Standing S Lockformer did not have one set of form rolls guarded.  c)    The Chicago Press Brake did not have the point of operation guarded in the front nor in the back of the press's die           area.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.219 F01

Serious Gravity 5 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.219(f)(1):     Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii):    Shop - Two sets of gears on the Pexto Electric Roller were not adequately guarded.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.213 B03

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.213(b)(3):     Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:    Shop - The Craftsman Table Saw was not provided with an anti-magnetic restart or similar device to prevent restarting of the saw after a power failure.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.213 D01

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.213(d)(1):     Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (c)(1) of this section for hoods for circular ripsaws:    Shop - The Craftsman table saw did not have a hood guard.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.303 G01 I

Serious Gravity 1 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.303(g)(1)(i):     The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1:    Shop - The space in front of the two electrical panels operating at less than 600 volts was blocked by pallets, 55 gallon drums and miscellaneous equipment such as dolleys, buckets and a box of flouroescent bulbs.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.178 L04 III

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(4)(iii):     An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.    At the Facility - The last time operators of powered industrial trucks were evaluated was in July of 2009.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Shop - The Lunalite portable multi-outlet strip was being used in an industrial type enviornment which was not a listed or approved area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View HSI MECHANICAL, INC.'s full OSHA safety record →