Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRIMAL SCREEN INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PRIMAL SCREEN INC. in 1021 MASON AVE, KENT, OH 44240 (NAICS 323113). OSHA activity number 336985999.

Watch Primal Screen INC. — free Get an email when a new federal OSHA severe-injury report for Primal Screen INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PRIMAL SCREEN INC.
Site address
1021 MASON AVE
City
KENT
State
OH
ZIP
44240
Mailing
1021 MASON AVE, KENT, OH 44240
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323113
Employees
11
Ownership type
A

10 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 11 exposed
Issued
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    On or about October 22, 2012, the employer did not guard a storage area that was at a height of approximately 8.5 feet located in the shipping and receiving area.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.151 C

Serious Gravity 5 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    On or about October 22, 2012, the employer did not provide a eye wash station to employees who were exposed to ER-650C which has the pH of 2 to 3.4
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.157 C01

Serious Gravity 5 1 instance 11 exposed
Issued
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    On or about October 22, 2012, the employer did not mount or make a ABC fire extinguisher readily accessible to employees located in the shipping and recieving department near the chemical mixing area. The fire extinguisher was blocked by boxes and was not mounted.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.157 E02

Serious Gravity 5 1 instance 11 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    On or about October 22, 2012, the employer did not have a ABC fire extinguisher located in the shipping and receiving department near the chemical mixing area visually inspected monthly.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E03

Serious Gravity 5 1 instance 11 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): The date of the annual maintenance check of portable fire extinguishers was not recorded:    On or about October 22, 2012, the employer did not have a ABC fire extinguisher located in the shipping and receiving  department near the chemical mixing area recorded with an annual maintenance check.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 5 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage space for cylinders was not located away from elevators, stairs, or passageways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    On or about October 22, 2012, the employer had a propane tank stored near a exit route and man door with a container of gasoline.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.157 G02

Deleted Repeat Gravity 5 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $3200.00 · Current $0.00 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    On or about October 22, 2012, the employer did not provide annual training for portable fire extinguishers when available for employee use.    PRIMAL SCREEN INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, (1910.157(g)(2)), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER (314416686), CITATION NUMBER 01, ITEM NUMBER 03, AND WAS AFFIRMED AS A FINAL ORDER ON (07/27/2010), WITH RESPECT TO A WORKPLACE LOCATED AT (1021 MASON ROAD, KENT OH 44240).
Recent events (2)
  • — I (R) $0
  • — Z (R) $3200

1910.147 C06 I

Other-than-serious 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about October 22, 2012 the employer did not review the energy control procedure at least annually.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 Q07

Other-than-serious 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    On or about October 22, 2012, the employer did not inspect powered industrial trucks on a daily basis before being placed in service.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 E

Other-than-serious 1 instance 11 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary:    On or about October 22, 2012, the employer did not mark the distribution panel located in the printing department with the voltage and other ratings.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PRIMAL SCREEN INC.'s full OSHA safety record →