Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JB FRICTION & FAB CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JB FRICTION & FAB CORP. in 704 10TH AVENUE, GRAFTON, WI 53024 (NAICS 332322). OSHA activity number 337005185.

Watch JB Friction & FAB Corp. — free Get an email when a new federal OSHA severe-injury report for JB Friction & FAB Corp. is published. One employer, no account, unsubscribe in one click.
Site address
704 10TH AVENUE
City
GRAFTON
State
WI
ZIP
53024
Mailing
704 10TH AVENUE, GRAFTON, WI 53024
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
11
Ownership type
A

12 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $800.00 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a)  The employer did not develop and implement a lockout/tagout program to ensure the de-energization of equipment prior to maintenance and/or servicing activities. Employees were exposed to struck-by and/or entanglement hazards.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(7)(i):     The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    (a)  The employer did not ensure that training was provided to employees authorized in lockout/tagout to ensure that the purpose and function of energy control was accomplished during maintenance and/or servicing activities. Employees were exposed to struck-by and/or entanglement hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1910.179 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.179(g)(2)(i):     Electrical equipment was not so located or enclosed that live parts would not be exposed to accidental contact under normal operating conditions:    (a) On the shipping/receiving dock, the pendant control for the CXT crane did not have all live parts enclosed in that the off button was missing. Employees were exposed to electrical hazards.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.179 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(2):     The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard    (a)  The employer did not ensure the CXT crane was inspected frequently to identify defects, such as but not limited to on the pendant control. Employees were exposed to struck-by and/or electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J03

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(3):     Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:    (a)  The employer did not ensure the CXT crane was inspected at least monthly to identify wear and deterioration of parts. Employees were exposed to struck-by and/or electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $800.00 Reduced
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) In the shop area, the Ermak hydraulic press brake did not have adequate point of operation guarding. Employees were exposed to crushing injuries.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1910.303 B07 I

Other-than-serious 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1910.303(b)(7)(i):     Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment    (a)  In the shipping/receiving area, a metallic utility box supplying power to the Sony stereo had an unused opening uncovered, exposing employees to electrical hazards.     (b)  In the shipping/receiving area, an electric panel for the spot welder and crane had an unused opening uncovered, exposing employees to electrical hazards.    (c)  In the storage room adjacent to the flatting oven, the breaker panel for the lights and air compressor had a missing switch and filler plate, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2000

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.1200(e)(1):     The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a)  The employer did not develop and implement a written hazard communication at the facility for employees using chemicals, such as but not limited hydrochloric acid. Employees are exposed to chemical burns.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.1200 H01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1):     Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area and chemical-specific information was not always available through labels and material safety data sheets    (a)  The employer did not ensure employees were provided the necessary training on hazardous chemicals utilized in the workplace, such as but not limited hydrochloric acid. Employees are exposed to chemical burns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1):     The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    (a)  The employer did not ensure a hazard assessment was conducted to ascertain appropriate personal protective equipment requirements for different operations, such as but not limited to chemical handling and/or material handling.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(i):     Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    (a)  The employer did not ensure employees using voluntary-use particulate masks were provided with the information outlined in Appendix D of the Respiratory Protection Standard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2):     Portable fire extinguishers were not visually inspected at least monthly:    (a) The employer did not ensure that portable fire extinguishers in the workplace were inspected, at least visually, on a monthly basis.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337005185.