OSHA Inspection: BERNICE REMODELERS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BERNICE REMODELERS, INC in 1293 LINWOOD AVE, COLUMBUS, OH 43206 (NAICS 236118). OSHA activity number 337031405.

Watch Bernice Remodelers, INC — free Get an email when a new federal OSHA severe-injury report for Bernice Remodelers, INC is published. One employer, no account, unsubscribe in one click.
Site address
1293 LINWOOD AVE
City
COLUMBUS
State
OH
ZIP
43206
Mailing
447 HIGHGATE AVE, COLUMBUS, OH 43085
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports.    a.  At the construction site located at 1293 Linwood Ave, Columbus, Ohio, employees were working replacing bricks on a chimney from an approximately twenty four foot tall scaffold that was not fully planked exposing them to a fall hazard.
Recent events (1)
  • — Z (S) $2800

1926.451 C02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.    a.  At the construction site located at 1293 Linwood Ave, Columbus, Ohio, employees were performing work replacing bricks on a chimney from an approximately twenty four foot tall scaffold that was not positioned on base plates for a solid foundation, thereby exposing the employees to a fall hazard.
Recent events (1)
  • — Z (S) $2800

1926.451 G04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(4)(i):     Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.    a.  At the construction site located at 1293 Linwood Ave, Columbus, Ohio, employees were working replacing bricks on a chimney from an approximately twenty four foot tall scaffold that did not have guardrails installed on any section, thereby exposing the employees to a fall hazard.
Recent events (1)
  • — Z (S) $2800

1926.452 C02

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.452(c)(2):     Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.    a.  At the construction site located at 1293 Linwood Ave, Columbus, Ohio, employees were working replacing bricks on a chimney from an approximately twenty four foot tall scaffold that had cross bracing missing on the fourth level exposing them to a fall hazard.    b.  At the construction site located at 1293 Linwood Ave, Columbus, Ohio, employees were working replacing bricks on a chimney from an approximately twenty four foot tall scaffold that had cross bracing missing on the third level exposing them to a fall hazard.    c.  At the construction site located at 1293 Linwood Ave, Columbus, Ohio, employees were working replacing bricks on a chimney from an approximately twenty four foot tall scaffold that had a brace connection not secured on the first level exposing them to a fall hazard.
Recent events (1)
  • — Z (S) $2800

1926.452 C05 III

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.452(c)(5)(iii):     Brackets used to support cantilevered loads shall:    Be used only to support personnel, unless the scaffold has been designed for other loads by a qualified engineer and built to withstand the tipping forces caused by those other loads being placed on the bracket-supported section of the scaffold.    a. At the construction site located at 1293 Linwood Ave, Columbus, Ohio, employees were installing brick and accessing the roof from a make shift wooden side bracket of a tubular welded frame scaffold that had wooden scaffold planks that extended perpendicular from the scaffold to the roof, which increased the tipping forces of the scaffold, thereby exposing the employees to a fall hazard of approximately 24 feet.
Recent events (1)
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13):     "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.    a.  At the construction site located at 1293 Linwood Ave, Columbus, Ohio, employees were performing work on a roof replacing bricks on a chimney of a residential home with an approximately 5 in 12 pitch and approximately 20 feet in height from the ground to the eave with no fall protection.
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337031405.