BROCKTON, MA —
OSHA Inspection: EAST COAST ERECTORS, L.L.C.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EAST COAST ERECTORS, L.L.C. in VETERANS ADMINISTRATION 940 BELMONT STREET, BROCKTON, MA 02301 (NAICS 238120). OSHA activity number 337057194.
Where did this inspection happen?
- Establishment
- EAST COAST ERECTORS, L.L.C.
- Site address
- VETERANS ADMINISTRATION 940 BELMONT STREET
- City
- BROCKTON
- State
- MA
- ZIP
- 02301
- Mailing
- 161 OGDEN LORD ROAD, MARLBOROUGH, CT 06447
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.62 D01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.62(d)(1)(i): The employer did not initially determine if any employee may be exposed to lead at or above the action level: Jobsite: The company did not assess employees lead exposure during the torch welding and cutting of lead-coated structural steel.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.62 D02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.62(d)(2)(iv): Until the employer performed an employee exposure assessment as required by 29 CFR 1926.62(d), and documented that the employee(s) performing any of the tasks listed in 29 CFR 1926.62(d)(iv) were not exposed to lead in excess of 2,500 micrograms per cubic meter, 50 times the Permissible Exposure Limit, the employer did not treat the employee(s) as if the employee(s) were exposed to lead in excess of 2,500 micrograms per meter cubed, and did not implement employee protective measures as prescribed in 29 CFR 1926.62(d)(2)(v): Jobsite: Employees welding and torch cutting lead coating were not treated as if their lead exposure exceeded 2,500 micrograms per cubic meter. For example, employees did not use respiratory protection or other appropriate personal protective equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.354 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.354(c)(2): In the open air, employees welding and cutting on lead coated structural steel were not protected by a respirator, in accordance with requirements of Subpart E of this part. Jobsite: Employees did not use respiratory protection while torch cutting and welding on lead-coated structural steel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D16 III
- Issued
- Abate by
- Penalty
- Initial $2040.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: Jobsite: Connectors used six foot lanyards along with 'beamers' to provide fall protection. This exposed them to potential free falls in excess of six feet.
Recent events (2)
- — I (S) $1428
- — Z (S) $2040
1926.753 D02 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.753(d)(2)(i): Materials being hoisted shall be rigged to prevent unintentional displacement; Jobsite: Metal decking bundles was rigged using two slings in a basket configuration. This exposed connectors receiving the bundles and persons on the ground to a stuck-by hazard from the improperly secured bundles.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.251 C09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.251(c)(9): Slings were not padded or protected from the sharp edges of their loads: Jobsite: Wire rope slings used to hoist structural steel were not protected from damage by the steels sharp edges.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.754 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.754(b)(3): A fully planked or decked floor or nets was not maintained within two stories or 30 feet (9.1 m), whichever is less, directly under any erection work being performed. Jobsite: The ground and first floors were only minimally decked. This exposed connectors working on the roof to potential falls into the basement of approximately 34 feet.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at EAST COAST ERECTORS, L.L.C.
BRISTOL, CT—2004-01-14 00:00:00
EAST COAST ERECTORS, L.L.C.
View EAST COAST ERECTORS, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
EL PASO, TX—2026-07-15
SURE STEEL
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
MIDLOTHIAN, VA—2026-07-09
B & J STEEL CONSTRUCTION, INC.
LYNCHBURG, VA—2026-07-09
GRAY'S WELDING LLC
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337057194.