Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KDM

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KDM in 2312 N BROAD STREET, PHILADELPHIA, PA 19121 (NAICS 238140). OSHA activity number 337065197.

Watch KDM — free Get an email when a new federal OSHA severe-injury report for KDM is published. One employer, no account, unsubscribe in one click.
Establishment
KDM
Site address
2312 N BROAD STREET
City
PHILADELPHIA
State
PA
ZIP
19121
Mailing
5402 WOODCREST AVE, PHILADELPHIA, PA 19131
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
1
Ownership type
A

6 citations on file for this inspection.

1926.405 A02 II E

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:  (a) Main Room, Worksite: On or about 10/24/12, temporary illumination lamps were not protected from accidental contact or breakage while employees were performing construction activities, exposing employees to potential injury.
Recent events (1)
  • — Z (S) $1600

1926.405 A02 II F

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights were suspended by their electric cords when such lights and cords were not designed for suspension:  a) Main Room, Worksite: On or about 10/24/12, temporary lights were suspended by cords that were not designed for suspension while employees were performing construction activities, exposing employees to potential injury.
Recent events (1)
  • — Z (S) $0

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines were less than 10 feet.  (a) Worksite:  On or about 10/24/12, unprotected high voltage power lines were located next to the third working level of a tubular welded frame scaffolding while employees were performing stucco operations, exposing employees to potential shock and electrocution.
Recent events (1)
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.   a) Worksite:  On or about 10/24/12, employees were not protected by the use of personal fall arrest systems or guardrail systems while working from a tubular welded frame scaffold, exposing employees to a potential fall hazard approximately twenty (20) feet to the ground level.
Recent events (1)
  • — Z (S) $2800

1926.451 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)   a) Worksite: On or about 10/24/12, employees were applying stucco to the wall of the building from the 2nd working level of a tubular welded frame scaffold platform that was not fully planked or decked.
Recent events (1)
  • — Z (S) $0

1926.20 B02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s)  a) Worksite:  On or about 10/24/12, the Employer did not establish a jobsite safety program which provided for frequent and regular inspections of the job site, materials, and equipment to be made by a competent person.
Recent events (1)
  • — Z (O) $0